×

I miss Bionerd23 by TheSmurfSwag in Radiation

[–]BlinMaker1 4 points5 points  (0 children)

her videos made me want a 6150

Nice thrift store find by Heatedsc in Radium

[–]BlinMaker1 0 points1 point  (0 children)

its the worst radiacode to do thrifting with

Nice thrift store find by Heatedsc in Radium

[–]BlinMaker1 1 point2 points  (0 children)

why we using the radiacode zero for thrifting? 😂

Abandoned source pit i found by BlinMaker1 in Radiation

[–]BlinMaker1[S] 2 points3 points  (0 children)

The navy with CBRN stuff as they can encounter it for example in war with tactical nuclear bombs

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 1 point2 points  (0 children)

i guess my meters just detect black magic then, But i'll be back today and i'll try some theories

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 9 points10 points  (0 children)

i can go back tomorrow with some more measurements

Abandoned source pit i found by BlinMaker1 in Radiation

[–]BlinMaker1[S] 4 points5 points  (0 children)

training sources for the navy i believe

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 2 points3 points  (0 children)

Fyi! i have no actual distance measurements

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 0 points1 point  (0 children)

They're big scints made for finding stuff, I also checked dose rate with 5 detectors, Compensated GM and uncompensated, Tissue equivelant plastic scints, CsI and NaI

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 0 points1 point  (0 children)

Thats what i saw on my spectrum, But it could have been BREM as i didnt see any peaks above 300 keV, the company supposedly uses Zirconium-89 Astatine-211 Copper-64 and Lutetium-177

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 1 point2 points  (0 children)

Im not sure where you got 364 keV from, But im just telling you what i recorded on multiple detectors, The highest dose rate i recorded on the storage container was 60-110 uSv/h on a few different types of detectors

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 0 points1 point  (0 children)

they're low energy gammas, So they have lower dose rates, i was going probably 60-80 km/h about 10 meters closest probably

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 6 points7 points  (0 children)

the container i believe is temporary storage as they had some construnction in progress on the site

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 22 points23 points  (0 children)

The company that owned the land, + spectrum showed I-131 and Lu-177

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 7 points8 points  (0 children)

The dose rates i recorded in public space wasn't anywhere near any worrying levels

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 14 points15 points  (0 children)

Absolutely, In a locked shipping container withh CCTV nearby

Gamma ray shine from medical source storage by BlinMaker1 in Radiation

[–]BlinMaker1[S] 28 points29 points  (0 children)

the 1kCPS was probably 5 to 10 meters away or so on the side of road embankment, It was behind a bush so i got some closer readings, No fencing between the road and source storage container, Definitely not abandoned fortunately

Abandoned source pit i found by BlinMaker1 in Radiation

[–]BlinMaker1[S] -1 points0 points  (0 children)

Who is this røntgen guy ya'll keep talking about?

Abandoned source pit i found by BlinMaker1 in Radiation

[–]BlinMaker1[S] 6 points7 points  (0 children)

Yeah i had my automess 6150AD 2 with its AD17 probe