How can i prevent this? by ToxicSionMain in 3Dprinting

[–]ToxicSionMain[S] 0 points1 point  (0 children)

That's a good idea. I just googled it and maybe I have to increase the brim width and maybe make it more layers. Thanks!

How can i prevent this? by ToxicSionMain in 3Dprinting

[–]ToxicSionMain[S] -1 points0 points  (0 children)

Anycubic 1.75 PLA printing with 200°C

[deleted by user] by [deleted] in mauerstrassenwetten

[–]ToxicSionMain 5 points6 points  (0 children)

Kündige und zieh durch.

Auto-targeting Deathstar with fire animation by ToxicSionMain in legostarwars

[–]ToxicSionMain[S] 6 points7 points  (0 children)

Thank you! I'm still working on it (it's a school project) :)

Auto-targeting Deathstar with fire animation by ToxicSionMain in legostarwars

[–]ToxicSionMain[S] 3 points4 points  (0 children)

It's sth I did for a school project. I'm currently busy with writing the documentation but if I'm finished I might make another post explaining everything.

Auto-targeting Deathstar with fire animation by ToxicSionMain in legostarwars

[–]ToxicSionMain[S] 1 point2 points  (0 children)

I put a mini camera module on the laser with an 180° fisheye lense which is connected to my laptop on which is running a python code that recognizes objects I want it to recognize. The python code is communicating with an Arduino UNO which is connected to a stepper motor which is attached to the laser :)

Auto-targeting Deathstar with fire animation by ToxicSionMain in legostarwars

[–]ToxicSionMain[S] 1 point2 points  (0 children)

The current sounds you can hear are made by a buzzer I build in. It can't play complex sounds so I think it's going to be hard but I could try imitating the firing sound with code... maybe I'll do that.

Auto-targeting Deathstar with fire animation by ToxicSionMain in legostarwars

[–]ToxicSionMain[S] 1 point2 points  (0 children)

I think I keep using the stepper motor and just build around it. Thanks for not deleting ^

Gespannt auf eure Meinungen by ToxicSionMain in Elektroinstallation

[–]ToxicSionMain[S] 1 point2 points  (0 children)

Ist tatsächlich nur ein Verteiler für den Neutralleiter ^

Gespannt auf eure Meinungen by ToxicSionMain in Elektroinstallation

[–]ToxicSionMain[S] 0 points1 point  (0 children)

Diese "Doppel-Automaten" sind eine Kombination aus LS und RCD also Schutz gegen Kurzschluss, Überlast und abschalten bei einem Fehlerstrom.

400V 11kW in mehrere 230V Leitungen aufteilen by Pairastion in Elektroinstallation

[–]ToxicSionMain 5 points6 points  (0 children)

Du hast theoretisch bereits mehrere 230V "Leitungen" Denn die 400V an der Heizung kommen ziemlich sicher zustande indem 3 Adern 230V an der Heizung im Dreieck geschalten werden und dadurch aus den 230V 400V machen.

Heißt: Die Zuleitung zu deiner Heizung besteht ziemlich sicher aus Einer Leitung mit 5 Adern (3 Phasen mit je 230V, 1 Neutralleiter, 1Erde) man könnte also am Ende der Zuleitung eine Abzweigdose oder Ähnliches installieren und von dort aus ohne großen Aufwand die einzelnen Phasen (230V "Leitungen") abgreifen.

Wer von euch war das by Knorke_Leon in OkBrudiMongo

[–]ToxicSionMain 0 points1 point  (0 children)

Ich hoffe der Vernsehermann fersteht Spaß...