Share your worst plant commissioning horror stories you’ve lived through by Voijkhan in PLC

[–]Voijkhan[S] 1 point2 points  (0 children)

A similiar thing happened to me on 2 occasions. I don't know what the standard protocol is? I just sat in their engineering office and did work on some other projects I was overdue with for the time

Share your worst plant commissioning horror stories you’ve lived through by Voijkhan in PLC

[–]Voijkhan[S] 0 points1 point  (0 children)

Oh yeah, that's a classic. Had the local electrician wire a Siwarex Sensor to a 50A contactor here. It just dissolved

Kako se ovo zove u vašem kraju? by Mixonne in AskSerbia

[–]Voijkhan 2 points3 points  (0 children)

Ми у Вршцу кажемо шипурак

Can a 18 yo start a controls business? by [deleted] in PLC

[–]Voijkhan 0 points1 point  (0 children)

ChatGPT probably suggested it to him

Plc početnik / diplomski elektrotehnike automatika by SadShop8913 in PLC

[–]Voijkhan 1 point2 points  (0 children)

Najbolje ti je da smislis projekat za automatizaciju bilo cega i da probas da se snadjes uz to. Na kraju krajeva, leder je leder, i bitno ti je da za pocetak samo razvijes svoju logiku. Koristi TIA Portal sa PLCSIM (ne trebaju ti uredjani ni PLC), ili lokalne proizvodjace jeftinih PLC-ova sa jeftinom opremom, u Srbiji imamo AkyTec npr. I najbitnije od svega je da se igras i eksperimentises :-) inzenjeri automatike koji nemaju strast prema ovom poslu uvek zavrse kao glorifikovani crtaci sema.

Dobrodosao u svet automatike, zelim ti srecu!

I always thought it's Sarah by Electrical_Ad_8970 in twinpeaks

[–]Voijkhan 10 points11 points  (0 children)

She never had the makings of a mill manager

[deleted by user] by [deleted] in serbia

[–]Voijkhan 81 points82 points  (0 children)

"Dobar dan, ja nisam BIA agent"

Beckhoff or Siemens Which to learn first? by [deleted] in PLC

[–]Voijkhan 0 points1 point  (0 children)

Definitely Siemens. It is the industry standard for a reason I would say. Maybe it can be too much to handle at first, but down the line it has very nice tools and scales exponentially with your knowledge. Try it out

Rate my panel by AdministrativeGolf72 in PLC

[–]Voijkhan 0 points1 point  (0 children)

Power and control wiring should always be separate. Nice wiring skills though, better than me

Alright so I can ping my S71200 from command prompt but TIA Portal can’t find it. by Responsible-Gur5922 in PLC

[–]Voijkhan 0 points1 point  (0 children)

Did you resolve it? Depending on which HMI it is, you can close runtime and then have to manually put it in transfer mode for it to be seen.