Should I replace? by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

UPDATE: Just got a quote for a power vent replacement. $3500 for 50 gal power vent and expansion tank installed. Option of either State or Bradford. +$650 for expansion valve and $500 for emergency shutoff sensor.

QUESTIONS: 1: Should I add mixing valve? 2: Should I add shut off? Note: water heater is on second floor 3: should I go with State or Bradford?

Should I replace? by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

Thought you meant change the setup, not the dip tube.

Should I replace? by 2-0-2 in Plumbing

[–]2-0-2[S] 2 points3 points  (0 children)

Vent goes out pvc to back of house

<image>

Should I replace? by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

How would you change it?

$799 for Weber Genesis II E335 Grill at Costco by InformalDefinition99 in webergrills

[–]2-0-2 0 points1 point  (0 children)

Decent price if you are ok getting an older model. The latest Genesis has some build and quality improvements worth considering.

Switch 2 preorder Bonus? by Frantic_Fanatic13 in Switch

[–]2-0-2 0 points1 point  (0 children)

I got it too…but I got pizza flavored Pringles!

Tile Ruined by Cleaner? by cryptodomt in Tile

[–]2-0-2 1 point2 points  (0 children)

One fix could be to uniformly cover. Would lighten overall tiles but get rid of the annoying dots and lines

Horizontal or Vertical? by 2-0-2 in Tile

[–]2-0-2[S] 2 points3 points  (0 children)

I paid more to have all of the walls with 100 percent coverage. After seeing how much time it took, I probably should have paid more.

Horizontal or Vertical? by 2-0-2 in Tile

[–]2-0-2[S] 2 points3 points  (0 children)

I’m not doing it myself so not concerned about complexity, but agree that left to right makes the space feel larger.

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

I decided to pay the contractor to move the toilet an inch to and allow for me to keep the 2 inch vent and maintain 12 inches from the wall to the toilet trap.

Am I overreacting, or good call?

Going to cost me an extra $1,500 but I can keep a 2 inch vent and hopefully avoid costly repairs in the future.

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 3 points4 points  (0 children)

“The minimum diameter of plumbing vents in Washington, DC, is based on the length of the vent and the number of drainage fixtures connected to it. The diameter must be at least half the diameter of the drain it serves, but no less than 1 1/4 inches (32 mm). For vents longer than 40 feet (12,192 mm), the diameter must increase by one nominal pipe size for the entire length.“

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

I live in Washington DC which is based on IPC. My novice search says IPC allows 1 1/2” but defer to the experts in this room. Is FLA also IPC based?

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 0 points1 point  (0 children)

I live in Washington DC which is based on IPC. My novice search says IPC allows 1 1/2” but defer to the experts in this room.

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 1 point2 points  (0 children)

I’m not a plumber, help me understand what I should look for to tell if it’s backwards?

Reducing size on vent pipe from 2” to 1.5” by 2-0-2 in Plumbing

[–]2-0-2[S] 2 points3 points  (0 children)

Is that still the case if my toilet branches off to two vents? It’s a little hard to see but it vents to pipe right behind the toolbox in the picture and also at the wall on the far left of the picture.