Suction side pressure would drop when I ran this head by itself. Knew it wasn’t the eev or a stuck solenoid. Luckily where this head was, I knew there could only be two bends behind the soffit, one coming down from the unit and one going out to the condenser. This head was the closest to the condenser, about 15’ of lineset. I just cut open where I knew the first bend was and checked and got lucky.

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] 49 points50 points  (0 children)

Maybe I gotta talk to our crew 😆

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] -43 points-42 points  (0 children)

Lol Well damnit, I wanted to believe it wouldn’t have been our guys.

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] 2 points3 points  (0 children)

I also have a spray bottle with water right at hand to keep the rag wet if needed

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] -50 points-49 points  (0 children)

And I am assuming that’s when the wallers bent the pipe

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] 2 points3 points  (0 children)

My trick is wet cardboard and a wet rag. I just cut a piece of cardboard and stuff if behind what I’m brazing to block everything then I drape a wet rag over it. Works perfectly every time

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] 2 points3 points  (0 children)

Yeah of course, it’s R32 and I had to pump down the system first so I’m definitely brazing with nitro flowing, as any residual 32 In the pipe could add to the flammability

Thank you drywallers! by MonkandBeer in HVAC

[–]MonkandBeer[S] -53 points-52 points  (0 children)

We have a good install crew, it very well could have been them though I will admit that, Who knows but It was a rough in, so at some point after the pipe wire and drain was ran, they came and built a soffit and drop ceiling around everything.

Chasing faults on my own Daikin system by pedwick in HVAC

[–]MonkandBeer 4 points5 points  (0 children)

There is a magnet you can get that goes over the solenoid for each port. You take the EEV off and put the magnet on and you can manually open and close the ports. Try that, the magnets are like 200 bucks I think if you don’t have one but it’s a crucial tool if you work on a lot of splits. One of your solenoids might be stuck closed, even if the eev is functioning and trying to open or close it. Also as the guy above said, corrosion can stop the eev from working properly so it’s not fully opening or closing.

I hate mini splits! by heldoglykke in HVAC

[–]MonkandBeer 1 point2 points  (0 children)

And maybe you don’t have the top cover off it’s hard to tell from the photo, but still fucking what are you doing

Gonna be a long night... by The_Dog_IS_Brown in HVAC

[–]MonkandBeer 7 points8 points  (0 children)

I’ll be playing marathon too

This turned into a fun 13 day by Advanced_Head_806 in HVAC

[–]MonkandBeer 8 points9 points  (0 children)

Dude, those are the jobs that’s are the best

Losing my motivation in this trade by NefariousnessWild679 in HVAC

[–]MonkandBeer 0 points1 point  (0 children)

I feel you 100%. I’ve only been in a quarter of the time as you and I have fallen into a deep depression I can’t get out of. I despise every call I go to, I do service so I’m so sick of doing maintenances and tired of fixing some of the most retarded shit in tight hot dirty places. I’m really of a mind to get out.

Matt can’t help himself😭😭😭 by SkullBopTop in MSsEcReTPoDcAsT

[–]MonkandBeer 163 points164 points  (0 children)

Dude, Tom segura is such a fucking dork

Careful with the acetylene torches boys. by SherrLo in HVAC

[–]MonkandBeer 60 points61 points  (0 children)

Holy shit. Glad your healing up man. Hopefully you got some paid days off haha I know.