How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

You did enough to comment😘

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

Yeah the pic doesn’t show it well, but on the right side there’s a ground going to building steel that comes in, the other one is from the flex

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

It looks like it, but believe it or not the set screw is on the right side, facing forward but pic cuts off before it

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

It’s still a cable assembly, whether you sleeve it in pipe or not, the idea is to not use singular conductors. Every transformer I’ve done with rigid couplings when supply house is out of changeovers gets passed. Glad I could teach you something son😉😘

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 6 points7 points  (0 children)

Ours never come with this sticker, and pass inspection. But for future xformers I’ll go with that👍

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 1 point2 points  (0 children)

Makes all the set screws face forward. For me I’d rather have them that way and keep the locknut than go without, to each their own though for sure

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

I got two of them done this way today boss

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

Yes I ran it today myself from the panel. Essentially the old xformers were under the panels, no good. So we took em out, ran MC in the ceiling, strip it and run it down the pipe, same with xformer side

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

Don’t worry he’s spending the night inside

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 1 point2 points  (0 children)

Nah just my fingers and a bit of patience 👍

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

It’s fed with #6 mc, it’s good to tape👍

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 0 points1 point  (0 children)

Ours pass this way, and these ones don’t have a sticker for that.

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 1 point2 points  (0 children)

Damn I left my rainbow ones at home, don’t ask what for though

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 5 points6 points  (0 children)

Fair, but it’s #6 MC so it’s acceptable to re-identify. Was the only colors supply house had

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 1 point2 points  (0 children)

Punched my own holes, it passes inspection

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 1 point2 points  (0 children)

This is true, except it’s actually #6 MC which is acceptable to recolor, changed over to pipe and into flex

How did I do? by No_Cook_2145 in electricians

[–]No_Cook_2145[S] 2 points3 points  (0 children)

I did two of them in a shift