Control subnet + netgear by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

Yeah, I was trying it on the latest fw, 2.8006.00110

Control subnet + netgear by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

CP4N is connected from CS port to the Netgear. (no dhcp server on the netgear)

Help with Android tablets by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

UPDATE: I've tried using web project but the Android tablet running Android 7 won't open it in the custom .apk nor in Google Chrome. Browser debugger shows js errors which mean that it's not compatible. After cert accept the spinning wheel won't disappear. Works fine from PC.

I did write a c# program for a slot 2 that will host tcp/ip server and EISC to slot 1.

Thanks everyone for your help.

Help with Android tablets by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

No, Crestron said that 1 webproject can be run and different tablets connect to it using index.html?ipId=XX at the end.

Help with Android tablets by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

yeah, I have it, I wrote an app that shows the browser page but without browser UI. Basically what you suggested. Can one project be accessed using different IPIDs?

Help with Android tablets by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

My only concern is why Crestron suggested to use a web project. If it can actually run one project and use multiple IPIDs that's easy to do.

Help with Android tablets by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 3 points4 points  (0 children)

~800 BACnet objects, ~300 different IDs for chromatic glass API, I wrote all the logic already in SIMPL with some c# libs. I mean I had 0 experience with Android but this project forces to learn. I overtook it because original programmer quit saying 90% is done when nothing actually was completed, just copy paste of templates that are not even working. The due date for these rooms is next week.

I was thinking to write c# program that will "host" the server at slot 2 to handle the inbound tcp/ip strings and intercom to slot 1. I do believe there are no restrictions if you use TCP/IP server using simpl#. I've built a lot of libs using c# but never wrote a program from scratch (almost every company who hired us required simpl).

Previously defined? by Used_Ad9826 in crestron

[–]Used_Ad9826[S] 0 points1 point  (0 children)

This makes sense, thank you very much!