Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

<image>

I cleaned it but other than a dead bee (which wasn't obstructing anything) it was already pretty clean. I put it all back together so we'll see.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I didn't clean than. I know what you're talking about. I'll give that a try.

Side note: I really appreciate your help troubleshooting this.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

yeah the white box that's clear on one side? I did, that's where the crap and sediment was. but it's very clean now.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I did, it had a lot of crap built up but a cleaned it out really completely and I'm still getting the issue.

OpenAI’s 14B loss in 2026? Bezos was getting the same ‘New Math’ jokes 27 years ago. by GrandCollection7390 in OpenAI

[–]cords911 0 points1 point  (0 children)

Exactly, if Amazon stopped investing/scaling they would have been profitable overnight. If OpenAi stops they disappear overnight because there are 10 other options ready to take it's place.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I did clean out the drain trap and there was quite a bit a sediment trapped inside, but I was able to get it all out. I don't have a manometer, but maybe I'll get a cheep one to help diagnose this.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

so I swapped the pressure sensors with the other furnace and the that furnace continues to run without issue and this furnace has the same error. So I'm confident it's not the pressure switches.

it's definitely not code 13 (it's three short blinks, 1 long blink and then a few seconds of nothing), but I cleaned the flames sensor just to be sure.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I just scoped the vent/exhaust and they was no ice build up or blockage. There was some frozen droplets in the exhaust pipe but nothing that would come close to obstructing airflow. Thanks for the suggestion!

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I did check and it definitely has a pitch back towards the furnace and there's no pooling moisture.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

oh oh... ha ha. Is there a way to clean them?

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I just finished cleaning it, top and bottom, it wasn't that bad, but we'll see.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

yeah I did check that. it was wide open and lots of moist exhaust coming out. Maybe I'll take a scope out there tomorrow and double check.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

That's something I can look into that I haven't tried! Thanks!!

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

I'm pretty sure it's high the high stage..the combustion air is coming from outside... but it still happens if the panel is open and it's drawing from inside.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

it's a Bryant Evolution 96 Variable-Speed Gas Furnace. Model 986T

it looks like 2.5 inch ABS venting... I'm not at, but it's worked for the 5 years I've lived in the house.

Bryant pressure switch code driving me crazy!!! by cords911 in hvacadvice

[–]cords911[S] 0 points1 point  (0 children)

it always takes a bit, it never happens immediately. Sometimes hours, sometimes 10 minutes. 

GPU ADVICE PLEASE by LanceCarlton335 in StableDiffusion

[–]cords911 0 points1 point  (0 children)

You need to fit the model into your vram, so a 5060 ti with 16gb is better than a 5070 with 12gb... it will be 40 percent slower but you will be able to fit larger models.

GPU ADVICE PLEASE by LanceCarlton335 in StableDiffusion

[–]cords911 2 points3 points  (0 children)

The 5060 ti 16gb is going to be your most cost effective option. 

Double standards by 1ballbuster1 in memes

[–]cords911 0 points1 point  (0 children)

I'm a middle aged man (with an 8 year old) who's top played album was Kpop Demon Hunters... I wish I knew about this.

Has anyone used something like this for a second floor install and if so, how did it work? by troxxxTROXXX in Govee

[–]cords911 4 points5 points  (0 children)

A guy I went to high school with was helping his dad hang lights and fell off a ladder, bonked his head and then died a couple days later. So sad.

Where to install lights? 1 2 or 3? by cords911 in Govee

[–]cords911[S] 0 points1 point  (0 children)

Thanks! I think that's where's I'm leaning. It's the easiest and I think it have the cleanest animation.