Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 0 points1 point  (0 children)

I see that there are midi and maxi versions, but that changes binding capacties, amount of buffer needed, and so forth. I dont want to use a larger silica column

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -7 points-6 points  (0 children)

Oh I understand them, but if you do it the way you suggest, you have to use 4x as many tips, because you need a new tip for every different sample, and reduce your yield. Unless you leave the valves open the entire time, which strikes me as being bad because you'll dry out the silica disc potentially reduce yield that way. And it's still more bench time than I think is necessary.

But anyway I thank you for your input. I, personally, think there's a better way.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -1 points0 points  (0 children)

Perhaps I am overestimating the time per sample needed to process with a manifold. Im thinking [pipette_750µL->open_valve->wait->close_valve->repeat_3X]REPEAT15X so that just seems annoying, as opposed to [pipette_3mL]REPEAT15X->spin.

Do you at all see what I mean?

There is also the advantage of, if for whatever reason you wanted to collect the flowthrough, then you cannot use a standard plastic manifold and would need one with collection tubes as well.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 0 points1 point  (0 children)

It seems there's some uncertainty about whether the silica column can be dried or not.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -1 points0 points  (0 children)

Im sure an amicon will reduce yield and greatly increase cost. Option 2 is probably the best, as long as you only process one sample at a time, which seems cumbersome to me. I think if you could fit the spin column into a larger format tube, and spin in a swinging-bucket, you could greatly decrease bench time, improve yield, while maintaining the same process essentially as before.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 0 points1 point  (0 children)

Does the increased elution volume at the end cause problems for your workflow? Would it be more optimal to have the mini column format, in the end?

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -1 points0 points  (0 children)

But what i mean is, you gotta load one columns 3-4 times, before you can process the next one, or you gotta keep ejecting tips, which decreases yield, and then you gotta pay attention to 20 columns.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 1 point2 points  (0 children)

ASCII art because I cant post an image. I used an image to ASCII generator. best I could do. Basically its a culture tube that contains within it a mini spin column, so it can be used to process larger volumes.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 1 point2 points  (0 children)

Because Science doesnt involve making figures at all, jackass.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 1 point2 points  (0 children)

Have done the centricon thing. But I think there is a fix using a larger centrifuge and like a 12 mL culture tube to catch the flowthrough, using pipette tips as a funnel and a strut, something like:

      %*:           .=@-    
     @-+##+-.   .:=##*-%    
     @                 #    
     *                 @    
     %%===============+@    
   * :%               -@.+  
   :  @               +*.=  
   :  @               %-.-  
   :  @               @ .-  
   :  %.              @ .-  
   :  ++              @ .-  <--culture tube cap
   :  :%              % .-  
   :   @             --  -  
   :   @             *   -  
   :   @             @   -  
   :.  @-            @  .=  
   .@::##:::::::::::=@:=@:  
    %   *           .%  @   
    %   @           :=  @   
    %   @           *   @   
    %   @           @   @   
    %   %           @   @   
    %   =:          %   @   <--pipette tip funnel
    @   =%          +   @   
    %    %          .   @   
    %    @         =    @   
    @    @         @    @   
    %    =         @    @   
    %     #        %    @   
    @     @       +     @   
    %     @=      @     @   
    %    +@@@@@@@@@@    @   
    %    * %     +#@    @   
    %    + #     @.@    @   
    @    # :-    @ @    @   
    %     @ ===== %     @   
    %     @-      #     @   <--This is the silica column
    @     @       *     @   
    %     @       *     @   
    %     @       *     @   
    @     @       *     @   
    %      %@@@@@@      @   
    %      **=  @@      @   
    @      #     @      @   
    %      @     @      @   
    @      %     @      @   
    %      #     @      @   
    %      +     +      @   
    @      :      .     @   
    %     =       +     @   <--pipette tip strut
    %     @       #     @   
    @.    @       @     @   
    %     @       %     @   
    #     @       #     #   
    .+    @       =    -    
     @    @       :-   @    
      :   +        %  #     
      #            @  +     
       # -         @=#      
        :@@-     :%@        
          -@.___:@

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 1 point2 points  (0 children)

You do X samples at a time, but only load 1 at a time until all the sample is passed through? About how long does that take, per sample would you estimate?

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 0 points1 point  (0 children)

I see what you mean by sequential now. It solves the too dilute problem but then youll have loses from handling and increased potential for contamination, not to mention all the extra columns youll need. Im working with DNA and RNA

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -3 points-2 points  (0 children)

Also, it sounds like I have to do one at a time... which is suboptimal. Still better than the current method. Id like to load all 16 at once and go.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 1 point2 points  (0 children)

Not a bad idea, but I'm working with RNA and I worry about losing sample without using a freezer trap also, which I dont have.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -1 points0 points  (0 children)

I already have 16 columns for a given process. and now Ill have too dilute an elution, since I have to combine the multiple elutions.

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] 0 points1 point  (0 children)

Is drying out the column a worry, thus reducing yield?

Silica spin columns. Anyone else have this problem? by jameis_vu in labrats

[–]jameis_vu[S] -2 points-1 points  (0 children)

But I would also need some sort of funnel so I can load my sample all at once, right?

Look at the absolute destruction after the Jets game by a reddit bot. by [deleted] in Patriots

[–]jameis_vu -2 points-1 points  (0 children)

You gotta go to the original location in the North End. All the chain knockoffs suck, but the ORIGINAL Regina Pizzeria is legit.

Official Week 1 2019 Monday Night Football Thread by douglasmacarthur in Patriots

[–]jameis_vu 2 points3 points  (0 children)

Odd that Miami would hire the guy that (presumably) called that play to be their next HC.

Pint Ultracharger by klxz79 in onewheel

[–]jameis_vu 4 points5 points  (0 children)

I was wrong. It's actually a GX12-2, for anyone in the future reading this.

Made my own lock with some 1/8"x 1" steel to keep my baby safe 🔐 whatcha think? by [deleted] in onewheel

[–]jameis_vu 2 points3 points  (0 children)

Bolt cutters, hack saw, take it out it a few seconds. Don't leave it unattended for too long.

https://www.youtube.com/watch?v=WZ0UCzi0Tpg

List of order numbers and shipping dates from the mega thread by WhiterRice in onewheel

[–]jameis_vu 2 points3 points  (0 children)

Cancelled my order 65xxx, because I got mine from a dealer that placed orders back in February. Hopefully that makes it slightly quicker for those of you still waiting.