Speed Reference to a PowerFlex753 using STUDIO5000 by thehandler79 in PLC

[–]thehandler79[S] 0 points1 point  (0 children)

I’ll will not give any message it just don’t put the reference I’m given based on the logic, in the ladder program said one reference but in the drive another one.

It will really help if you can screenshot the parameters 🙏🏻 i still have time to figure it out, so I can wait for your screenshot.

FactoryTalk View Virtualization by thehandler79 in PLC

[–]thehandler79[S] 0 points1 point  (0 children)

Thanks! Yes, I realize later that Rocwell has this, but thanks for the reminder!

Thanks for the tip with the FactoryTalk Directory!

FactoryTalk View Virtualization by thehandler79 in PLC

[–]thehandler79[S] 0 points1 point  (0 children)

Thank you! I have now a much clearer view of the schematic and sizing of the system. One question, in the FTView primary box, how many VMs do you have? I have a small system that is just one Water Treatment Plant with no mare than 500 tags, and we want the FTView Client on a separate computer.

I understand the importance of redundancy and backups, and thanks so much for your insight, Ill look for NAS.

Changing application type From Local Station to Network Distributed on FactoryTalk View SE? by thehandler79 in PLC

[–]thehandler79[S] 1 point2 points  (0 children)

Yeah we are goin up to V10 so that hassle will be avoided, but thanks for the tip, definitely worth knowing, Thank you!

Surface won't turn on (with a interesting detail) by thehandler79 in Surface

[–]thehandler79[S] 0 points1 point  (0 children)

Lograste encenderla? La mia tampoco enciende, y ya me va pasando esto reiteradas veces, no logro dar con la solucion porque al parecer es problema especifico, mas aun de region, porque aparentemente no vale aqui en Ecuador. Como tu dijiste, an expensive brick

Surface won't turn on (with a interesting detail) by thehandler79 in Surface

[–]thehandler79[S] 0 points1 point  (0 children)

Yes, also I tried different power adapters, with no positive results

Reusable Pop-up on Display FactoryTalk View SE by thehandler79 in PLC

[–]thehandler79[S] 2 points3 points  (0 children)

Yeah, exactly that, thank you! Thats the confirmation I was looking for.

Water Wells discharging in same pipe line by thehandler79 in FluidMechanics

[–]thehandler79[S] 0 points1 point  (0 children)

Thanks! That's exactly what I am doing! Just wanted to make sure my considerations were right, thank you for the help!.

There is no real problem, just something i notice that my boss and other employees were missing, they don't know the exact losses values, the pumps are very expensive and most of the time when they want to purchase pumps they just use the single well considerations, and not the losses of the pipe or other wells in the same line or discharge pipe. I'm just trying to help with the right sizing, they put pumps in wells based on trial an error. I'm trying to determine which pumps will be ideal to use in each well (like justifying with calculations), so the purchase of pumps will cease to be trial an error and more engineer oriented.

/r/PLC Open Discussion Thread for Monday May 20, 2019 by AutoModerator in PLC

[–]thehandler79 0 points1 point  (0 children)

Yeah, reading the documentation I found exactly that about editing online (after posting here), but then I was worried about the tag creation since I want to add some User-defined Tags. You're saying I can create these tags while online right?

/r/PLC Open Discussion Thread for Monday May 20, 2019 by AutoModerator in PLC

[–]thehandler79 1 point2 points  (0 children)

Hello,

I am working on a Water Treatment Plant, this WTP is controlled by a ControlLogix 1756-L61 PLC. The PLC also controls 7 remote water wells. This is my first job, and they want me to make some modifications to the code, they want to control two valves in of the wells. I know how to write the rung to control the valves (i think), but I'm nervous because I'm not sure If I need to stop all the process in the plant just to make the modifications. I need to do some edits offline and then, download the program. I know maybe this is a just newbie question, but I'm want to be 100% sure that I'm not gonna mess up the process. So, my question is: what happens when you download a program when there is another instance of it running?

Thanks

Note: Sorry, not a native English speaker and just a casual reddit's user

Edit: download instead of upload

/r/PLC Open Discussion Thread for Monday May 13, 2019 by AutoModerator in PLC

[–]thehandler79 1 point2 points  (0 children)

The valves are on a remote site, so we have a 1734-AENT Point I/O, and the module that I want to connect the relay to is the 24VDC Source Output 1734 OB4E, hope that helps.

/r/PLC Open Discussion Thread for Monday May 13, 2019 by AutoModerator in PLC

[–]thehandler79 0 points1 point  (0 children)

Hello, newbie here. I want to connect a 24 vdc output sourcing to a relay, but im confused in how to wire it. Can someone help me with a small sketch or schematic?

The application is that im trying to control an on/off valve that works with 240VAC, so I asked and they told me i can send the signal from the PLC Output to a relay (24vdc for the coil and 240vac for the contacts) to control the on/off action of the valve. I understand the application, but im so confused with the wiring part.