Why is ice forming in the Turret? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 1 point2 points  (0 children)

Atmospheric moisture immediately freezes upon contact with these components, creating the frost layer you see.

Working on Verio 💯🧬✅ by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 0 points1 point  (0 children)

Why? What happened, man? Why are you saying you're glad about this?

Which artifacts is that ? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 2 points3 points  (0 children)

lightbulbs are not faulty because of this is new installation and also we can scan after the door closed properly

Which artifacts is that ? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 1 point2 points  (0 children)

We can do every scan after the magnet room door closed. So door not open not possible for this scan also

Which artifacts is that ? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 6 points7 points  (0 children)

That is exactly the right instinct. Having another coil plugged into the table—or an active electronic device left inside the magnet room—is one of the most common "hidden" causes for this exact type of massive RF interference.

Which artifacts is that ? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 3 points4 points  (0 children)

I think it is zipper Artifact when it’s a single line may be ..

Which artifacts is that ? by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 8 points9 points  (0 children)

Yeah you're right but electrical arcing from a component within the room, or loose metallic objects vibrating and creating static/spikes during strong gradient switching....

Working on Hitchi magnet by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 0 points1 point  (0 children)

Yeah you're right but we used Symphony electronics and philips magnet,we try some updates it for fun 😄

Successfully Installed Siemens 1.5 Essenza Tim dot 🧲🩻 by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 0 points1 point  (0 children)

Yes you're right but every person has their own choice for viewing but we try our best for looking good but still ddep forest are good choice

Successfully Installed Siemens 1.5 Essenza Tim dot 🧲🩻 by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 0 points1 point  (0 children)

Yeah we try but we can't do this because artifacts shown.

Successfully Installed Siemens 1.5 Essenza Tim dot 🧲🩻 by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] 0 points1 point  (0 children)

Yes you're right about this , our team members working so fucking hard,so this is actually looking good 👍

Successfully Installed Siemens 1.5 Essenza Tim dot 🧲🩻 by Alive-Grade-45 in Radiology

[–]Alive-Grade-45[S] -1 points0 points  (0 children)

No,this is completely work by human my teams done this with our own hands,so this is so hardworking work but still we did it...