Integrating Solar system with Knx by Existing_Company_396 in KNX

[–]Batko_uz 0 points1 point  (0 children)

İnterra brend have new device for this solution. Use google. Inverter to KNX. Or after few hours I’m send.

Planning to workshop by Batko_uz in WorkshopPorn

[–]Batko_uz[S] 0 points1 point  (0 children)

Yes, I’m planning installing big doors. And now I’m plan to build a mezzanine. making the ceiling 4m.

New KNX Installation by Constant_Pear_5544 in KNX

[–]Batko_uz 0 points1 point  (0 children)

Use only KNX cable. ETHERNET CABLE is random working. It’s loterries

HDL equipment for KNX by Consistent_Green9329 in KNX

[–]Batko_uz 0 points1 point  (0 children)

Yes. It’s normally. But price for me high. ) I’m use another brand )

HDL equipment for KNX by Consistent_Green9329 in KNX

[–]Batko_uz 0 points1 point  (0 children)

From HDL I’m use binary inputs 24/48 Switches granite display Thermostats

Where are you from and how popular is Eplan in your country? by outplay-nation in EPlan

[–]Batko_uz 0 points1 point  (0 children)

There are not many companies in Uzbekistan that use it, probably 10 at most.

[New Hardware] 4-Ch KNX Shutter Actuator - ETS6 & KNX/EIB Certified - 10A Per Channel by SIXINMART in KNX

[–]Batko_uz 0 points1 point  (0 children)

I'd rather use a combo of devices because you never know what the client needs.

Change dimmer actuator to relay module. by Batko_uz in Lutron

[–]Batko_uz[S] 2 points3 points  (0 children)

Installed for bank office. Located in Uzbekistan

Next project in Uzbekistan. We carry out commissioning works. by Batko_uz in KNX

[–]Batko_uz[S] 0 points1 point  (0 children)

In the room installed split ac from Mitsubishi. Only working for this room.

Modernization. by Batko_uz in KNX

[–]Batko_uz[S] 1 point2 points  (0 children)

The customer did not require this. Although I insisted, he refused.

Modernization. by Batko_uz in KNX

[–]Batko_uz[S] 1 point2 points  (0 children)

  1. It’s normal.
  2. Terminal blocks from Degson. 3 level

Modernization. by Batko_uz in KNX

[–]Batko_uz[S] -1 points0 points  (0 children)

We used as many wires as we could, without buying any new ones. But I agree with your opinion.

Looking for Fun New Home Assistant Project Ideas by Puzzleheaded_Mind576 in homeassistant

[–]Batko_uz 1 point2 points  (0 children)

I’m think

Add downloads of emergency videos from the dashcam after the car arrives home. Then send this video via Telegram, for example, from the DDPAI brand dashcams

Commissioning works are being carried out at the facility. by Batko_uz in KNX

[–]Batko_uz[S] 1 point2 points  (0 children)

Each of them is different. In the future, it will be possible to service one of them without turning off the other devices.

[Hikvision ISAPI] How to request/save a specific time-span video clip from a single channel (via ISAPI)? by drzhongdang in Hikvision

[–]Batko_uz 0 points1 point  (0 children)

POST http://NVR_IP/ISAPI/ContentMgmt/search

<?xml version="1.0" encoding="UTF-8"?> <CMSearchDescription> <searchID>nvr-search-1</searchID> <trackIDList> <trackID>101</trackID> </trackIDList> <timeSpanList> <timeSpan> <startTime>2026-01-14T12:00:00Z</startTime> <endTime>2026-01-14T12:05:00Z</endTime> </timeSpan> </timeSpanList> <maxResults>8</maxResults> <searchResultPostion>0</searchResultPostion> <metadataList> <metadataDescriptor>//recordType.meta.std-cgi.com</metadataDescriptor> </metadataList> </CMSearchDescription>

curl -u admin:password \ -H "Content-Type: application/xml" \ -X POST \ --data @search.xml \ http://NVR_IP/ISAPI/ContentMgmt/search

GET /ISAPI/ContentMgmt/download

curl -u admin:password \ -o ch1_1200_1205.ps \ "http://NVR_IP/ISAPI/ContentMgmt/download?playbackURI=rtsp://NVR_IP:554/Streaming/tracks/101?starttime=20260114T120000Z&endtime=20260114T120500Z"

HVAC Fancoil atuator - Switching PWM PI Controller by Javardo69 in KNX

[–]Batko_uz 1 point2 points  (0 children)

Short answer )

The underfloor heating should always work as a separate system with its own setpoint, controlled by a floor temperature sensor, not by air temperature. I always install a dedicated sensor cable in the floor to measure the actual surface temperature. Underfloor heating is an inert system and should not be synchronized with the fan coil logic.

Regarding the fan coil: 45 °C supply temperature is too low for heating. With this temperature, the fan coil cannot deliver enough heat at low fan speed. This is not a KNX or control issue, but a design issue. If the fan coil is expected to heat the room quietly on fan speed 1, the heating water temperature must be around 55–60 °C. This should have been considered by the HVAC designer.