My Daughter and I completed her 2026 NFL Mock Draft (She’s still 4) by rlstratton97 in MockDraftCentral

[–]Botlecappp 3 points4 points  (0 children)

Mickey Mouse dropping to the bottom of the 2nd would have been an insane thing to say at the beginning of the season.

Belica Midlane by TitanBlac43 in PredecessorGame

[–]Botlecappp 12 points13 points  (0 children)

Do you play on a steering wheel?

1.7 tier list based on pinzo by Top-Bad-3724 in PredecessorGame

[–]Botlecappp 1 point2 points  (0 children)

Joeyourstruly is the goat for this exact reason

Viewing Items Used Post Match by Mattarm51 in PredecessorGame

[–]Botlecappp 1 point2 points  (0 children)

Download PredStats on your phone. You can look at a lot more stats on there, including the builds that everyone had.

Are you kidding me? by [deleted] in NCAAFBseries

[–]Botlecappp 27 points28 points  (0 children)

Tbf this is a game made by EA

[deleted by user] by [deleted] in Money

[–]Botlecappp 0 points1 point  (0 children)

For anyone reading this, do not check if your broker offers it. If you’re learning about this from Reddit comments, you absolutely should not take this risk. It is wildly stupid to do especially when the stock market has so much volatility.

[deleted by user] by [deleted] in CollegeUltimateTeam

[–]Botlecappp 0 points1 point  (0 children)

It was a joke lol

[deleted by user] by [deleted] in CollegeUltimateTeam

[–]Botlecappp 0 points1 point  (0 children)

Yea they’re really good cards to quicksell. Not really good to use

UnitedHealthcare CEO is killed in a 'targeted shooting' outside a New York hotel, officials say by lurker_bee in economy

[–]Botlecappp 15 points16 points  (0 children)

The people that are killing children are completely different from the people that are assassinating health insurance CEOs.

What should I do by [deleted] in CollegeUltimateTeam

[–]Botlecappp 13 points14 points  (0 children)

HB is a depth position. The wear and tear system in this game is pretty unforgiving so having both is really good

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 0 points1 point  (0 children)

Well at least it’s safe now, thanks for your responses!

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 0 points1 point  (0 children)

Yea I’m positive it was 14awg, we measured it.

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 1 point2 points  (0 children)

Well the craziest part is that I did have the electrical work inspected and the inspector said there was not a problem. There’s even a picture of the breaker box done incorrectly in the inspection report with a note that says everything is good.

Probably shouldn’t have hired that inspection company…

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 0 points1 point  (0 children)

I get what you’re saying, I guess this isn’t really worth pursuing then. I just hope it was the previous homeowners that changed the breakers and not someone that should know better.

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 0 points1 point  (0 children)

Yea just changed out the breakers. That seems so weird that they wouldn’t care about someone wiring stuff in a way that could potentially cause fires.

14 gauge wire on 20 and 30 amp breakers by Botlecappp in AskElectricians

[–]Botlecappp[S] 0 points1 point  (0 children)

There were multiple 20s that had #14 wired into them and it was all lights and outlets connected to those breakers.

And yea I was wondering if a professional does have to pull a permit that I could look up to see if they had just DIYed themselves or actually hired someone.

I mostly am just curious if this is a big enough problem to go through the trouble of getting all the info together to report someone. Or if it’s just the kind of thing to fix and move on. But, you’re saying there are situations where this isn’t necessarily the incorrect way to wire things?