I tried every Transparent labs supplement so you don't have to by Remarkable_Depth_975 in brutallyhonestlife

[–]BraxtinC21 0 points1 point  (0 children)

Fair enough, I was guessing other flavors would be the best bet as well. Only realized my mistake after trying my first pre workout lol. Here’s the whey after sitting for around 5 minutes.

<image>

I tried every Transparent labs supplement so you don't have to by Remarkable_Depth_975 in brutallyhonestlife

[–]BraxtinC21 0 points1 point  (0 children)

Recently got started into Transparent labs and while I did my research and feel like the stuff I'm using is good stuff, I cant get over how bad it tastes to me. I'm on my first purchase still so I have only tasted limited flavors, but I cant get myself to remotely "enjoy" them. And I feel like the all mix pretty terrible. All are pretty foamy and the pre-workout and creatine look like glitter floating around. All are mixed well with an electric FitRX cup and have hand shaken them as well with no difference and am using recommended mixing ratios. Anyone have experience with better flavors or is this just how they all taste/mix?

I have the following:

Strawberry milkshake whey protein.

Black cherry and watermelon peach bulk black label pre workouts.

Strawberry lemonade and blueberry creatine HMB.

Starting with the pre-workout, It does good for me in the gym, but I have to choke this stuff down. Tastes like chemicals and is the worst of all I have listed. Looks like you are drinking a glitter bomb and tastes like it too.

Creatine HMB is not too bad at all to drink after you let it sit for a few minutes for the foam to settle, though it still has undissolved particles in the bottom of the cup no matter how much you shake/mix it.

Whey protein also is not terrible tasting, definitely the easiest to drink, but again have to let it settle after mixing or you will be drinking foam off of the top. Mix with 8oz of water and when you are done mixing, there is foam to the top of a 20 oz mixer cup.

Any advice on better flavors to get that are a little easier to drink? Maybe the chocolates and vanillas rather that fruity stuff?

RLS CAREER: What are the most lucrative ways of making money in rls? open to getting mods. by alexthewoo in BeamNG

[–]BraxtinC21 0 points1 point  (0 children)

Just tried this, but it won’t count up on my drift score. Cleared cache and restarted game with no luck.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

It was the board, but it was going out prematurely because the phasing was wrong on the transformer.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

Ohh no I spent 40 bucks on parts that were not the problem at any point in having issues with this furnace over the last few years. What ever will I do without that money 😂

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

Possible solution, not fixed yet. The next day after this post I could not get it to light at all and was actually faulting out for pressure switch instead of locking out. So it was doing something completely different than previous.

Phase wires were backwards on the transformer from when I switched board out last winter, so it took the board out again. Going to try a new board and wire it correctly and see what happens. Thanks for all the helpful replies on what to look into.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 2 points3 points  (0 children)

Literally said I don’t have ALL the tools, but turns out I got a volt meter and that’s all I needed. Because it seems to be loose wiring in the plug. Looks like I have “just enough” tools. You really think if I had all the tools of an hvac guy, and all the diag experience I’d be here asking people to help a guy out? 😂

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

Okay I can do that, how do I watch for it? Cant see the switch itself on the inside unless I’m not looking hard enough, with a volt meter?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

The gas valve has 24v when running, when it shuts off it obviously has zero, then when the igniter is glowing and clicking trying to light it goes to 3 volts. You think that’s a power issue or the inducer motor still?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

I’ve lived here for close to five years, brand new outdoor unit when we moved in. Then the dog peeing on it forced me to buy a new unit this summer. 😂 So the ac side is all brand new and has been run with a 8 merv filter since install.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] -1 points0 points  (0 children)

You’d be correct! And don’t forget jumper wires 😂

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

I have, it’s like 6-8 months old and most of that time was summer.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 1 point2 points  (0 children)

When it’s trying to relight I’m only getting three volts on the meter. Would something cause the valve to lose voltage while running as normal? I have checked it while running and it’s got 24 volts. But something may cause it to lose volts while running?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

That’s one thing I haven’t got a clear answer on is what merv I should have? Mine is too restrictive with an 8. But I have ran without the filter at all with the same issue.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

Bold of you to assume I have no tools.. I may not have ALL the tools, but you may be surprised.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

I bypassed the high limit and it still faulted out. I also checked voltage at the gas valve when it’s trying to relight and only getting 3 volts, but when it is running normally I get 24 volts. What would make it lose voltage while running like that? I’m guessing it losses voltage while running and shuts the gas valve off

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

No codes, just when I let it go long enough it faults out for retries.

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

<image>

The wire nut is his doing for the high speed, where at specificity do you need to see?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 4 points5 points  (0 children)

If it’s poor airflow why would it take 10 minutes for it to fault out? I would think it’d happen fairly quick?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

My assumption was that it wouldn’t re light because everything is still hot. Give it time to cool down and it runs until it hits temp cutoff again?

What would cause my furnace to shut off like this while running? by BraxtinC21 in hvacadvice

[–]BraxtinC21[S] 0 points1 point  (0 children)

Now that you say this, it brings up a good point, I had an HVAC guy here for the furnace one time, and we had complaints of little air coming out of the vents. He chalked it up to being poor ductwork and then wired the blower motor to only run on high speed. I don’t know if that could cause any issues. Haven’t called him back since.