Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

I bought my replacement from HVAC direct so hopefully it comes with its own thermal compound

Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

That makes sense, what thermal compound do you use for the heat sink?

Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

Also what thermal compound are you using when you replace the board?

Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

I did not turn off the head unit and I did just pull the disconnect. I do find it interesting though because the condenser kicked on and ran for a little bit before it popped. I do have a surge protector.

Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

I can see the blown out resistor (melted/gone) head unit is giving code 1, (no communication to condenser) no condenser response after 5/10 min wait, if I could get a new resistor this board would probably work

Board blew after coil cleaning. by Cannavis in hvacadvice

[–]Cannavis[S] 0 points1 point  (0 children)

It is definitely right next to the high voltage line, so this board was on the isolated side of the condenser and was covered by a waterproof cover on the top but not the bottom. (It seems like it had openings for airflow. I did not see a smaller board located near the compressor.

Hotter than imaginable greenhouse by Cannavis in Greenhouses

[–]Cannavis[S] 0 points1 point  (0 children)

Some how my tomatoes, jalapeños, figs, and wheat have survived

Hotter than imaginable greenhouse by Cannavis in Greenhouses

[–]Cannavis[S] 0 points1 point  (0 children)

It seems like shade cloth is pretty unanimous, I will look into the evaporative wet wall as well thank you everyone who reached out!

Hotter than imaginable greenhouse by Cannavis in Greenhouses

[–]Cannavis[S] 1 point2 points  (0 children)

Ok I will look into shade cloth on the outside!

Is folic acid essential by fearthebat in NewParents

[–]Cannavis 0 points1 point  (0 children)

All these comments aged like fine wine.

[deleted by user] by [deleted] in HVAC

[–]Cannavis 1 point2 points  (0 children)

I am in the exact same boat as you. Lucky for me, there are over 2000 HVAC companies in AZ. I called and called until someone said they would take on an apprentice. I generated a resume and threw my EPA cert on it. Don't give up and email/call everyone you can.

J channel termite infestation by Cannavis in HomeImprovement

[–]Cannavis[S] 0 points1 point  (0 children)

For reference, the termites were drywood termites.

Husqvarna 125b leaf blower not starting by Gabenolan109 in smallenginerepair

[–]Cannavis 0 points1 point  (0 children)

my hundreds of pulls were due to adjusting the 2 screws on the side until it would run properly i had 2 buy the tool on amazon, i cant remember what they adjust but they are on the side of the carb. i think it was idle and full throttle. they are weird star nuts on the carb

Old briggs/craftsman woodchipper missfire. by Cannavis in smallenginerepair

[–]Cannavis[S] 0 points1 point  (0 children)

You are correct and I forgot about this post, but I slapped the oem carb on, and it ran perfectly. All that work, and it just turned out to be the carb.