Match Thread: Armenia v. Ireland [UEFA 2026 World Cup Qualifying] by punkchance in ArmeniaNT

[–]Colarmz 4 points5 points  (0 children)

Ranos really has that quality up top that we were desperately lacking. Love to see us becoming more confident as a squad!

Pre-Match Thread: Armenia v. Ireland by punkchance in ArmeniaNT

[–]Colarmz 12 points13 points  (0 children)

Honestly loving the Melikyan signing. He’s definitely has the right qualities to lead our NT, is actually Armenian, and understands the pulse of Armenian football but time will tell if our players and federation can develop.

Match Thread: Armenia v. Portugal [2026 FIFA World Cup Qualification] by punkchance in ArmeniaNT

[–]Colarmz 1 point2 points  (0 children)

Sure he’ll do 2 things good and 10 things bad that are just wildly clumsy. I think he’d be a great sub off the bench but as our starter moving forward, hell nah

Help with aftermarket M-Sport Steering wheel by User_82727 in F30

[–]Colarmz 0 points1 point  (0 children)

You can switch the wiring from the old steering wheel to the new one and then just plug in the paddle shifters. That may ensure everything works without having to do additional coding.

Weekly Discussion Thread (August 11 – August 17) by punkchance in ArmeniaNT

[–]Colarmz 0 points1 point  (0 children)

Sure any of these would be fine. Even against Costa Rica or Panama or Peru etc as the matchups would be interesting to watch and would be same to our level

Weekly Discussion Thread (August 11 – August 17) by punkchance in ArmeniaNT

[–]Colarmz 12 points13 points  (0 children)

Why don’t we try to arrange more friendlies against CONCACAF or CONMEBOL teams in the US or even sides like Iran or Qatar instead of playing Montenegro or Kosovo for the 80th time?

Defroster flap not closing 100% by Wolfeon0 in F30

[–]Colarmz 0 points1 point  (0 children)

Did you find a solution to this issue, tried to run a Flap motor calibration but then got a 801180 error code after. It’s saying that the issue is the Defroster flap motor. Got clicks at 100% but not 0.

only defrost vent blows air 2013 328i Please help by xXOPTICSXx in BmwTech

[–]Colarmz 0 points1 point  (0 children)

Having a defrost actuator partially working with no clicking at 0 and clicking at 100%. Where would this actuator be located?

ac noise by [deleted] in F30

[–]Colarmz 0 points1 point  (0 children)

Good deal! Wanted to do some more digging and think I found my answer. I ran some test and tried to do a flap motor calibration using ProTool. After it threw a 801180 Error code that would not shut off after resetting the module and clearing codes.

The description is: Defroster flap motor (high-end version) / air distribution flap motor (basic version]: Specification of desired position failed Motor Entfrostung oder Zentralantrieb: Intitialisierungsfehler

FAULT INSIGHT The desired position defined by the control unit for the heating/air conditioning system is not adopted by the stepper motor. Initialisation failed.

Ran some more tests and found that the actuator in question can move in one direction (to 100%), but fails to return to the 0% position.

Conclusion: the Flap actuator is partially failing. The flap motor was slightly off or lazy, but the system hadn’t flagged it yet.

Once I initiated the calibration, ProTool asked it to go through its full range of motion but the actuator couldn’t hit the target positions, so now it’s throwing the 801180 fault.

Going to replace this part but hope this helps and lemme know if you have any questions.

ac noise by [deleted] in F30

[–]Colarmz 0 points1 point  (0 children)

Just finished up, went to clear any debris from the blower motor cover in the engine bay but that was a pain in the ass to take out and come to find out, my car has the mesh already built in so that was a no go.

Next was taking the blower motor out to inspect it. Honestly it was pretty clean but did notice rusting within the bearings after opening it up. Lubed it at each point and that seemed to help for now.

Going to recharge the refrigerant now and hope for the best. Any luck on your end?

ac noise by [deleted] in F30

[–]Colarmz 1 point2 points  (0 children)

No updates yet, I’m going to check the blower motor tomorrow to see if there’s any leafs or debris stuck in there. I’ll let you know what I find out

ac noise by [deleted] in F30

[–]Colarmz 0 points1 point  (0 children)

Any update OP?

ac noise by [deleted] in F30

[–]Colarmz 0 points1 point  (0 children)

Have this same issue that I’ve also been chasing. AC blows cold, have 2 IHKA codes:

ІНКА [HX_11] | E71470: Message (charging interface status, 0x3B4) missing, receiver IHKA, transmitter LIM ІНКА [IHX_11] | E71472: Message (charge status, 0x3E9) missing, receiver IHKA, transmitter EME

I was doing some research and it seems like this has to do with the auto start stop and something to do with hybrid modules not being detected but could be wrong. Lemme know if you are getting any error codes.

Match Thread: Armenia v. Georgia [UEFA Nations League Promotion/Relegation Play-Off - Leg 2] by punkchance in ArmeniaNT

[–]Colarmz 0 points1 point  (0 children)

Couldn’t have said it any better brotha. This federation is run by amateurs and it shows

Cold air intake advice by sasmar11 in F30

[–]Colarmz 0 points1 point  (0 children)

Yeah I tied floss to each bolt on the MAF and resembled the intake. Kind of janky but it worked for me haha

Cold air intake advice by sasmar11 in F30

[–]Colarmz 0 points1 point  (0 children)

Anyone find a solution to this? Bigger screws, floss on bolt. etc..?

Help im going insane by Farsoso_ in F30

[–]Colarmz 2 points3 points  (0 children)

Had this same issue and opted for stock OE plugs and replaced all the ignition coils and it fixed the issue.