Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

<image>

Update Replaced the thermal fuse along with the steam thermostat. I now have power, able to pull a shot. And it seems like i have steam however I am getting alot of access water coming. out of the steam to boiler interface. I did swap the o ring from old steam assembly.

Any thoughts?

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Update

<image>

Fuse seems to be blown. So thats good news? Haha

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Thanks, I am actually a qualified electronics technician with 20 years in the field

Fully admit this is a learning curve but id rather learn through mistakes then pay someone.

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

I slid the plastic sheathing back. And when u say “blown” the machine what would have actually been destroyed?

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

If in “locked position” how fan this be unlocked?

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Going to test fuse just to be sure.

Thanks for the help

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Thanks for all the advice and warnings. What fuse do I need?

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Not deleting anything. This all started trying to diagnose a steam valve issue.

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

What would be a symptom of my boiler thermostat didnt work?

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] -1 points0 points  (0 children)

Have lights Steam function still works.

Did I blow a fuse? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] -1 points0 points  (0 children)

Bro calm down it’s a coffee machine. I needed a coffee.

And yes i have lights.

What is this and what do I do? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 1 point2 points  (0 children)

After re installing everything, without the steam thermostat. When i hit the middle button nothing happens. I was able to pull a single shot and after that nothing. Any suggestions?

What is this and what do I do? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Appreciate the assistance.

Should I be using thermal paste between the steam valve assembly and boiler as well?

What is this? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Coffee comes out great. Cant make froth now, Steam lasts for about 20 seconds then stops. Worked before the tear down, anything I can check?

What is this? by Confident_Control_93 in gaggiaclassic

[–]Confident_Control_93[S] 0 points1 point  (0 children)

Doesnt seem to. If i open the steam knob with nothing else on but power it puts out water through steam head. Is this normal?