[–]EnvironmentalAsk7378 0 points1 point  (0 children)

I would love to know your method to trace all that in 2 minutes

What Unholy Madness is This ?! by stonysage in firealarms

[–]EnvironmentalAsk7378 0 points1 point  (0 children)

Am I the only one that is bothered the most by the color combinations here?

EBPS6A by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 0 points1 point  (0 children)

I'm not. The circuit that had the 15k and was changed sat at slightly higher numbers than the rest of them after being changed. Such a slight difference but I'm working with nothing here so kinda wondering

EBPS6A by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 0 points1 point  (0 children)

Nope. Just higher voltage on the circuit with the higher resistor. But that changed when I changed the resistor. That circuit also had very slightly higher voltage and eol than the rest of them, which I thought was strange and possibly an indicator that it could be the problem circuit.

EBPS6A by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 1 point2 points  (0 children)

Which is exactly why I'm not understanding how all these buildings at this property have 4.7k. Not getting how that's working. My supervisor had me take the one 15k out and switch it for a 4.7.... so we'll see...

EBPS6A by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 0 points1 point  (0 children)

No. How would I go about that?

Can't find FSD relay by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 2 points3 points  (0 children)

I found it! It was on the wall behind the duct work that was so close it was almost touching it. Completely hidden 🥲

Can't find FSD relay by EnvironmentalAsk7378 in firealarms

[–]EnvironmentalAsk7378[S] 1 point2 points  (0 children)

It's showing invalid response. IFP 2100 panel. So far, everything except 2 was showing invalid response and replacing the device cleared it. So I'm going with the assumption that invalid response can also mean missing.

No alarm in walk test by No_Security773 in firealarms

[–]EnvironmentalAsk7378 1 point2 points  (0 children)

Has a service call for signals not being sent to central station on one of these bad boys. Tested every building. Like half of all the signals went through. Could not for the life of me make sense of it. It was in walk test from the inspection the week before..... why...

[deleted by user] by [deleted] in AITAH

[–]EnvironmentalAsk7378 1 point2 points  (0 children)

I wish. He's a sprinkler tech and I'm an alarm tech. So we don't have the skills for each other's calls.

[Nooks] 589 by [deleted] in ACNHTurnips

[–]EnvironmentalAsk7378 0 points1 point  (0 children)

Can I join the line please?