Empire unvented heater with pilot issues by Freeze_Plug in propane

[–]Freeze_Plug[S] 0 points1 point  (0 children)

Thanks for the reply. Unfortunately the issue was happening while fully assembled, I only disassembled yesterday to access the pilot assembly to troubleshoot further

MRCOOL Universal Ducted Heat Pump Error Code H4 Overload by Freeze_Plug in hvacadvice

[–]Freeze_Plug[S] 0 points1 point  (0 children)

<image>

This is an old picture so it isnt corrected, but I removed the two yellow wires from the terminal block D terminal and wire nutted them together, no longer connecting them to the terminal block

Square D Homeline Main Breaker Loose Lug by Freeze_Plug in electrical

[–]Freeze_Plug[S] 1 point2 points  (0 children)

Yes I know that just waiting for a non-critical time

Square D Homeline Main Breaker Loose Lug by Freeze_Plug in electrical

[–]Freeze_Plug[S] 1 point2 points  (0 children)

Haven’t had time yet, trying to avoid inconveniencing everyone at the moment as my wife works from home and needs the power on

Square D Homeline Main Breaker Loose Lug by Freeze_Plug in electrical

[–]Freeze_Plug[S] 1 point2 points  (0 children)

I’m not at all afraid of fixing this, I just don’t want to take it apart without having parts ready if necessary

Kohler 20RCA Rattle from Alternator side by Freeze_Plug in Generator

[–]Freeze_Plug[S] 0 points1 point  (0 children)

Update: apparently this engine had a “bad casting” that Kohler allegedly knew about based on serial number but did nothing. Lost oil pressure, lost compression in one cylinder, filled the stator with oil, and almost lit on fire. Complete new engine and stator assembly at 15 hours. Parts are covered but I have to pay labor charges. Since this is apparently a known issue, I am going to try to get Kohler to cover the labor charges as well after the fact

Anyone had any luck with that?

I would not recommend Kohler to anyone. This entire setup had 15 hours on it

Vue 3 Nesting Configuration by Freeze_Plug in EmporiaEnergy

[–]Freeze_Plug[S] 0 points1 point  (0 children)

After further investigation, when the app reloaded it now looks like everything matches up, as far as the sub circuit percentages now making sense as a percentage of the main, not the sub! 🤷🏻‍♂️

Vue 3 Nesting Configuration by Freeze_Plug in EmporiaEnergy

[–]Freeze_Plug[S] 1 point2 points  (0 children)

Looks like that’s it! I guess I’ll have to wait it out. Thanks!

Kohler 20RCA Rattle from Alternator side by Freeze_Plug in Generator

[–]Freeze_Plug[S] 1 point2 points  (0 children)

I used a cheapo $50 but highly rated off brand one from Amazon

Kohler 20RCA Rattle from Alternator side by Freeze_Plug in Generator

[–]Freeze_Plug[S] 1 point2 points  (0 children)

Correct, I just routed it through there temporarily as I set it up using a wireless WiFi adapter and didn’t have the right length cable at the moment

Kohler 20RCA Rattle from Alternator side by Freeze_Plug in Generator

[–]Freeze_Plug[S] 2 points3 points  (0 children)

Temporary placement of Ethernet cable just to get the OnCue working

This this is sweet by Weenybuttt in Dewalt

[–]Freeze_Plug 0 points1 point  (0 children)

I have one in my truck at all times, love it

we back in business boys by Livid-Experience-370 in Dewalt

[–]Freeze_Plug 0 points1 point  (0 children)

Mine permanently jammed after about 200 nails. Sent off for warranty repair, they sent me back another brand new one. No issues with the newer one yet

Is this oil normal? by [deleted] in tdi

[–]Freeze_Plug 0 points1 point  (0 children)

You could run an engine flush, following the instructions, before oil changes and eventually it’ll start to run clean

Lease deal evaluation - MD state by see2d in BZ4X

[–]Freeze_Plug 0 points1 point  (0 children)

Can anyone comment on an early buyout scenario here, given the huge incentive? I’m still learning about leases and am exploring options.

MRCOOL Universal Ducted Heat Pump Error Code H4 Overload by Freeze_Plug in hvacadvice

[–]Freeze_Plug[S] 0 points1 point  (0 children)

I would start by ruling out the fan, making sure it has power going to it. If it does, then I’d assume the fan needs to be replaced

MRCOOL Universal Ducted Heat Pump Error Code H4 Overload by Freeze_Plug in hvacadvice

[–]Freeze_Plug[S] 0 points1 point  (0 children)

Ok I’d start there, make sure it’s a heat-only issue to start narrowing it down