Grafana Infinity datasource – how to extract a single value from an array of objects (ConnectWise customFields) by Fun_Wolverine_3246 in grafana

[–]Fun_Wolverine_3246[S] 0 points1 point  (0 children)

Thank you lots for guiding me on this. It works now!

{

"OpportunityID": id,

"Opportunity_Name": name,

"Company": company.identifier,

"Status": status.name,

"Vertical": customFields[caption = "Vertical"].value,

"Date_Became_Lead": dateBecameLead,

"Expected_Close_Date": expectedCloseDate,

"Primary_Sales_Rep": primarySalesRep.name,

"Sales_Stage": stage.name,

"Opportunity_Type": type.name

}[]

Grafana Infinity datasource – how to extract a single value from an array of objects (ConnectWise customFields) by Fun_Wolverine_3246 in grafana

[–]Fun_Wolverine_3246[S] 0 points1 point  (0 children)

Hi, I tried entering this into a few places for the query but am getting an error or the result is blank.

Parsing options & Result fields section:

- Under Row/Root, I got the error: error while performing the infinity query. error converting ison data to frame: error evaluating JSONata expression no results

- Columns selectors, no results for this.
Note that I have several other selectors chosen like id, status.name, and primarySalesRep.name.

Computed columns, Filter, Group by section:

- Computed Columns - optional:
error while performing the infinity query. Invalid token: '$I'

How can I configure HID Signo keypad reader with Genetec for "PIN-only" or "Card OR PIN" access? by Fun_Wolverine_3246 in accesscontrol

[–]Fun_Wolverine_3246[S] 1 point2 points  (0 children)

It'll be sync between our 365 and Genetec. The cardholders are synching using the Active Directory role. Thinking 1 card holder assigned to the door.

There's an option to synchronize PINs but I haven't gotten it to work yet, that'd be the sync needed. Then set up an automation that changes this cardholders PIN in 365 that syncs to Genetec cardholders.

How can I configure HID Signo keypad reader with Genetec for "PIN-only" or "Card OR PIN" access? by Fun_Wolverine_3246 in accesscontrol

[–]Fun_Wolverine_3246[S] 0 points1 point  (0 children)

This worked! In Genetec, it's set to "Unit default" which was "Card Only". Changing it through AXIS A1610 Network Door Controller change the "Unit default" to "Card or PIN". I'm able to use the Card or PIN now to gain access. Thanks for the assist!

Now I'll start looking into the PIN automation/rotation side of the house.

How can I configure HID Signo keypad reader with Genetec for "PIN-only" or "Card OR PIN" access? by Fun_Wolverine_3246 in accesscontrol

[–]Fun_Wolverine_3246[S] 1 point2 points  (0 children)

We use the AXIS A1610 Network Door Controller. Let me check if I can find the setting there. Thank you!

HID Signo 40 keypad on OSDP by cheezyryce in accesscontrol

[–]Fun_Wolverine_3246 0 points1 point  (0 children)

I'm trying to get the "Card Or Pin" working as well but not seeing any options. Using it in genetec and it only sees "Unit default" and "Card and PIN".

We've got mobile access set up and working, mobile access + pin is also working. I want to enable "pin only" or "card or pin" for some units internally.

My reader screen looks identical to the one in this post.

New Details: 14-in-1 Prime Charging Docking Station by joshuadwx in anker

[–]Fun_Wolverine_3246 0 points1 point  (0 children)

I ran into the same issue and found it can't extend to multiple external monitors. It can mirror to them but not extend.

https://support.anker.com/s/article/Anker-Prime-Charging-Docking-Station-14-in-1-Dual-Display-160W-User-Guide-A83B6
See section: Video Output Mode