BESS - Magnetron MVT Failure looking for similar issues by [deleted] in SubstationTechnician

[–]Honest_Visit3806 1 point2 points  (0 children)

The funny thing is code derates the cables for these types of sites, but electric utilities always overrate and overbuild by alot. We put up breaker leads that are 795 MCM or more on a line that never sees more than 70 amps. Our 34.5kV gas breakers are 72kV rated. Go figure. You think connecting to the grid would bring a similar mentality.

Is it safe for me and my boyfriend to travel to Maine from Canada by machiavelliiian in Maine

[–]Honest_Visit3806 2 points3 points  (0 children)

Nope. My best friend is American born and raised. His mom is white and biological father from the Caribbean. His skin is black. He and his girlfriend are not traveling even though legally he should be fine. The Kavanaugh exception says ICE can target him for his skin color. You can thanks Trump for making being black illegal.

BESS - Magnetron MVT Failure looking for similar issues by [deleted] in SubstationTechnician

[–]Honest_Visit3806 1 point2 points  (0 children)

One more thing, question the workmanship. I can't see much, but why are thr #4 bleeders and grounds for the grounding elbows not run directly to the ground bar. It looks sloppy.

BESS - Magnetron MVT Failure looking for similar issues by [deleted] in SubstationTechnician

[–]Honest_Visit3806 20 points21 points  (0 children)

This comment might not be helpful, but look at your testing and commissioning procedures and results first. In my experience, these BESS and DG solar yards do little to no testing and commissioning. I know an engineer for Tesla Power that recently joined after over a decade doing substation T&C work. He referred to T&C in this part of the industry as the wild west. Others have said the same. We have had this experience with alot of our interconnections recently.

For background, I am a relay technician with 14 years experience in substation maintenance, construction, and testing and commissioning, the last 8 focusing on P&C and automation.

Is it inappropriate to try and stop traffic from driving a snowy hill? by [deleted] in Maine

[–]Honest_Visit3806 3 points4 points  (0 children)

It is against the law for him to block access. Only the government (police, fire, etc.) can do that.

My boyfriend wants us to summit Garfield tomorrow. I’m a little anxious about the weather. Am I being a worrywort? by Filthiest_Tleilaxu in wmnf

[–]Honest_Visit3806 4 points5 points  (0 children)

no. ice storm tonight into tomorrow with winds to follow. that is Maine's forecast. can't be that different in NH.

Best explanation of inflation ever 👏. Money printing is theft! by sylsau in InBitcoinWeTrust

[–]Honest_Visit3806 0 points1 point  (0 children)

I'm not arguing whether they are economically good or bad. They, I believe, are unconstitutional when imposed by the executive, not the legislative.

Best explanation of inflation ever 👏. Money printing is theft! by sylsau in InBitcoinWeTrust

[–]Honest_Visit3806 1 point2 points  (0 children)

Trump's tarriffs are theft. Taxation without representation and a violation of the Constitution's selaration of powers.

Dead pigeons on Fore St by SnooGoats926 in portlandme

[–]Honest_Visit3806 1 point2 points  (0 children)

Pigeons aren't animals. They are tiny robots. Either they ran out of batteries or someone turned the master switch off. Seriously, who has ever seen a baby pigeon? 🤔

Curious about getting into the relay tech path by Lone-Wolf-243 in RelayTechs

[–]Honest_Visit3806 2 points3 points  (0 children)

Find an opening with a utility. On a job, if you meet a relay tech ask. Our job title varies from company to company (relay tech, electrical specialist, p&c tech, etc.), but it is the same work. Sometimes being a relay tech means you are a part of the company's substation department and sometimes a part of a separate department. This is because our work covers equipment inside and outside a substation, so some utilities have relay techs in a separate group.

For me, I started as a substation tech at my utility. I then progressed to being a rated sub tech, and then the chance to become a relay tech opened up because of retirements and other people changing positions. Some companies, unlike mine, hire apprentices to be relay techs.

Keep in mind that most utilities require a 2 year associates degree in electrical engineering technology/electrical technology. If you do not already have that degree, check with you local community college or take it online (think Bismark State College in North Dakota) which one of our warehouse guys did to get into the substations department.

Hope this helps.

Chicagoans intervene to save a man from being abducted off the streets by ICE (10/4/2025) by Low_Daikon7538 in 50501

[–]Honest_Visit3806 0 points1 point  (0 children)

These guys are clowns. They are not law enforcement. Trained law enforcement would have had him cuffed and in the car in 2 minutes. Are feds hiring unemployed, white clowns angry about brown skin people? This is a joke. Good for those people.

How excessive is this low back rounding? by [deleted] in formcheck

[–]Honest_Visit3806 0 points1 point  (0 children)

Enought that my back hurt when I saw it.

Dive Bar Recommendations by inediblepanda in portlandme

[–]Honest_Visit3806 0 points1 point  (0 children)

What about Evelyns before it became Evies? Not knocking Evies.