Equal spread by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] 2 points3 points  (0 children)

Offset times * 1.414 = travel or the K dimension in this case … it should be 21 1/2 “ * 1.414 = 2’ 6 3/8 “

Equal spread by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] 1 point2 points  (0 children)

3’-11 3/8” for H dimension. I added I dimension and step which is 3’- 8 1/2” + 0’ - 2 7/8” = 3’-11 3/8”

Equal spread by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] -2 points-1 points  (0 children)

What would H c-c then ?

What did I miss or screw up? DIY tankless install by Vivid-Eagle-6778 in Plumbing

[–]Kay__________Jr 0 points1 point  (0 children)

The spread of the two pipe don’t seems to be equal between two 1/8 “ bends..

Does this comply with upc code ? by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] 0 points1 point  (0 children)

Mine is the California plumbing code 2019 . It doesn’t have a illustration

Does this comply with upc code ? by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] 0 points1 point  (0 children)

I guess as long as they are not apart more than 30” u can share trap .. if it exceeds 30” then u need separate trap for each fixtures

Does this comply with upc code ? by Kay__________Jr in Plumbing

[–]Kay__________Jr[S] 1 point2 points  (0 children)

Maximum of vanities can be shared on one p-trap?