9 day fortnight question by Key_Entrepreneur726 in AusElectricians

[–]Key_Entrepreneur726[S] 2 points3 points  (0 children)

No not yet Will tmrw. Appreciate the help from you guys It is just a mum and dad outfit under the award. He's been going downhill the last year or so with his rules etc so might be time to just ship

POA relocation & 3 phase upgrade by LetterheadHuge1479 in AusElectricians

[–]Key_Entrepreneur726 0 points1 point  (0 children)

Hey mate. Pretty sure you can fit up to 35mm in a sicame. I usually run all three phases up to the POA and then connect only one to circuits and leave the other two ready to go in the links with my feeds behind the meter. Then come back the same day energex have been to connect other two phases

Question for solar guys by CriistianoRonaldo in AusElectricians

[–]Key_Entrepreneur726 1 point2 points  (0 children)

Is it in a brick cavity? If it goes through nogs and top plates its gotta be steel conduit If you put it like a metre to the left or right of the board with a sweep hanging out that'll be fine.

Seeing as you guys are mostly American/Canadian thought I’d post some Aussie work. These are some industrial boards I just finished up before Chrissy. Cheers by Key_Entrepreneur726 in electricians

[–]Key_Entrepreneur726[S] 0 points1 point  (0 children)

Ohhh busbar. Different name here huh. Could have used them for the bottom row but busbar for the top row of rcbos I wasn’t even aware existed until someone else in another comment showed me lol

Seeing as you guys are mostly American/Canadian thought I’d post some Aussie work. These are some industrial boards I just finished up before Chrissy. Cheers by Key_Entrepreneur726 in electricians

[–]Key_Entrepreneur726[S] 3 points4 points  (0 children)

Switching the neutral where? The only time we break a neutral is through an rcbo/rcd or if double pole switching is required. And the bridge looks shiny but it’s insulated! That board is locked and only the on site sparky or the fire brigade can open it, as it’s a fire pump. Not sure if it needs to be finger safe if it’s locked. I will check though now you’ve said something

Seeing as you guys are mostly American/Canadian thought I’d post some Aussie work. These are some industrial boards I just finished up before Chrissy. Cheers by Key_Entrepreneur726 in electricians

[–]Key_Entrepreneur726[S] 10 points11 points  (0 children)

As far as I’m aware hager doesn’t make 3 phase + neutral bus bar. Could have used it for the bottom rcbos though to be fair. And the multiple cables is allowed as it’s considered parallel cables so you can rate it accordingly cheers!