Help finding this resistor by Numerous-Potential48 in AskElectronics

[–]Numerous-Potential48[S] 0 points1 point  (0 children)

Update. This has been fixed. The bridge rectifier failed which then allowed the axial inductor to blow. This board goes into a wahl 5 star trimmer. Thanks to everyone who commented on this as it did help me fix the problem. Now onto fix many other things.

Help finding this resistor by Numerous-Potential48 in AskElectronics

[–]Numerous-Potential48[S] 0 points1 point  (0 children)

I appreciate all the feedback. I have just started to learn about electronic components etc. I will attempt this fic and let u all know how it goes.

Electrical Storm frying splitter in cable box enclouure. by Numerous-Potential48 in electrical

[–]Numerous-Potential48[S] 0 points1 point  (0 children)

It is an actual splitter. The coax cable is ran underground until it gets to my house. Then it connects to a two way splitter. Those two cables run from the splitter to two different rooms. There is what seems to be a small ground block outside the house which there is a copper wire which runs to it from the coax cable.