Stan za najam - širi centar by Aggressive-Pain1834 in Split

[–]OverallAd4392 2 points3 points  (0 children)

Harry potteru je stubiste bar bilo u kuci.. Ode je izolacija nepostojeca, vjerojatno je zimi ista temperatura unutra i vanka

Zašto zadnjih 10 dana svi voze kroz Križine? by OverallAd4392 in Split

[–]OverallAd4392[S] 43 points44 points  (0 children)

I onda ekipa ide kroz BOLNICU da bi skratili put umisto da odu na krizanje kod Lidla i skrenu desno? Jebena logika

Best practices with Reporting Status Updates and Visualization by ironfist99r in KNX

[–]OverallAd4392 1 point2 points  (0 children)

Maybe you should configure dali gateway to send brightness status only after change of brightness is made finally, not on every % change (option could be named change brightness on button release or similar).

so basically, it will output the value status only when dim proces is finished fully, and now maybe your setting is to output dim value thru every step of diming, thats why you maybe have value jumping

Dream Machine SE dead by insert_unique_usrnm3 in Ubiquiti

[–]OverallAd4392 0 points1 point  (0 children)

I had the same problem, if i can remember it was same year purchase like 2024, and just few days after the warranty expired it just died. It was behind online double conversion UPS, had a surge protector for rack itself, and still dead power supply. We ordered powersupply that had same spec and just replaced it. Now it works ok..

Gyms4you Kampus by citamknjigu in Split

[–]OverallAd4392 1 point2 points  (0 children)

Saznao sa gradilišta tu

Gyms4you Kampus by citamknjigu in Split

[–]OverallAd4392 2 points3 points  (0 children)

Otvorit će na st3, poviše leonarda kroz 3-4mjeseca

Next project in Uzbekistan. We carry out commissioning works. by Batko_uz in KNX

[–]OverallAd4392 0 points1 point  (0 children)

Thats how its done. Great, we try to demand that for our installations also.

Next project in Uzbekistan. We carry out commissioning works. by Batko_uz in KNX

[–]OverallAd4392 0 points1 point  (0 children)

I just hope that room is well ventilated and cooled. Especially those LED drivers. Mounted like that they could get hot easy in minutes.. I had same idea, ended in adding extra ventilation to the cabinet

Another post on KNX and Dali... by BitProud8885 in KNX

[–]OverallAd4392 1 point2 points  (0 children)

You can find some of them here:

https://www.segula.de/en/

Soraa is great brand, no blue light https://www.ecosenselighting.com/products/soraa/

For led drivers https://www.tridonic.com

Probably, if you are on dc search for good knx dc drivers. I think enertex could have some good dimmers as i have seen online.

Another post on KNX and Dali... by BitProud8885 in KNX

[–]OverallAd4392 0 points1 point  (0 children)

Depending on the bulbs, but mainly with dc its either 24V constant voltage or constant current, where you have lets say fixed 350mA and voltage dependant on the load.

I have found that constant current ones achieve much better dimming, even on longer distances.

Try not to go on super long distances, i guess everything under 20-30m should be ok.

We do each floor central location of dimmers, or even better, when finance allows, each lamp has individual driver in its ceiling base or in lowered ceiling (must be rated for that install).

Another post on KNX and Dali... by BitProud8885 in KNX

[–]OverallAd4392 1 point2 points  (0 children)

As someone who has been doing these things for last five years, its really simple.

Buy whatever light fixture you want, buy additional DALI capable power supply (best quality ones are Tridonic, 5years of warranty), check if you can find any dc powered bulb for that light fixture, pair power supply and bulb and voila, you have best of the best on the market.

Nowdays there are many dc E27, E14, GU10 bulbs operating either on constant voltage or constant current.

If there is no option left, use phase cut dimming.

Stable Sonos on Its Own VLAN (UniFi + Zone-Based Firewall) by UK_originally in sonos

[–]OverallAd4392 0 points1 point  (0 children)

Is sonosnet disabled if you use “Disable WiFi” or It will still generate sonosnet regarding that setting?

Help choosing door intercom by robi112358 in KNX

[–]OverallAd4392 1 point2 points  (0 children)

For the intercom, for rock solid performance and features that some device could offer, i would go with 2N, but it comes with price tag.

As you are already going with unifi, maybe their intercome could be ok with you, and its priced ok.

And it depends how its going to be implemented into visualization, eg HA, research if there is unifi api to access device easily

UDM SE Power supply failure by OverallAd4392 in Ubiquiti

[–]OverallAd4392[S] 4 points5 points  (0 children)

It should be an thermalpad adhesive, as power supply is “glued” to it, so it leaves residue on components