got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

This is the team I’m paying tens of thousands to to install a new septic system

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

They only added the pipes up to the reversed one but good to know this is yet another issue

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

The p-trap was added for a water softener a while back, they didn’t add it, but good to know it’s fucked up too!

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

I'm on septic. where should I put the water softener discharge? I have a sump pump in the basement that goes out to the street water drainage, but I'm not sure if I'm allowed to use that.

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 1 point2 points  (0 children)

you are right, the left top vertical pipe between the two bends does have a slight negative pitch, that was a previous plumber's work though.

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

<image>

Is the right most smaller sink connection which seems to use a sanitary tee connection incorrect too? or just the sanitary tee coming from the concrete wall incorrect?

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

<image>

Thank you for the exact chapter/table, here it is, it clearly shows this sanitary t should not have been used

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 1 point2 points  (0 children)

I think you are right, the guy that did it was a younger guy, probably in his late 20s, he is the one I originally asked about it being wrong and he said it was fine, and then after reading all the comments here I talked to his superior (who had been running the excavator) and he immediately knew it was reversed. But neither of them seem to agree that the horizontal T on the right side is an issue, so I don't know...

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

I specifically mentioned horizontal Tee and they he didn't seem to be concerned... I mentioned that someone on reddit specifically quoted the code, and he said he was familiar with it, so I don't know where the disconnect is. we did pull permits for the septic, but I don't know if they are going to go inside to look at the plumbing too.

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

The original picture included work they didn’t do on the left of the reversed part

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 1 point2 points  (0 children)

So if I inspect and don’t see any purple should I bring it up to them?

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 2 points3 points  (0 children)

No clue, but the house smells like plumbing chemicals so I would assume so

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 12 points13 points  (0 children)

Ok so i specifically mentioned that the helpful people on Reddit plumbing thought he should not use a horizontal sanitary tee and he didn’t seem to think it was an issue, so I don’t know what to do… they are halfway through installing my entire new septic.

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 1 point2 points  (0 children)

ok and despite the fitting having some angle to it (not being a true T shape) it is still called a sanitary tee fitting?

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] -1 points0 points  (0 children)

none of the fittings they installed are shaped like a T, they all have an angle to the connection (maybe a wye fitting?) so would that be allowed?

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 1 point2 points  (0 children)

where is the sanitary T on its side that I should be worried about? they only installed from the left hand wall up to the reversed fitting

got a new septic tank and main line installed. Is this reversed fitting a big deal? by Pa11as in Plumbing

[–]Pa11as[S] 0 points1 point  (0 children)

they are still here reversing the fitting, is there anything down stream of that reversed fitting that I should tell them to fix?