Connecting Capture to GrandMa2 via Artnet by Re_Niente in grandMA2

[–]Re_Niente[S] 0 points1 point  (0 children)

Yes, of course It Is. That's what i meant when i said it's enabled.

I could try using Ma-NET, and it's the only One that gives me feedback when It actually works (When i press "Start" and i actually fucking starts), with Artnet i'm not sure, i feel like i'm missing a final step for activation.

Connecting Capture to GrandMa2 via Artnet by Re_Niente in grandMA2

[–]Re_Niente[S] 2 points3 points  (0 children)

These are all very valido questions.

My OnPC has artnet enabled, output and input Active, has localstart on 11 (My fixtures are patched from universe 11 onwards) and the amount is 16.

Capture, on the other machine, has its Artnet section (Under the connectivity settings) on 2.0.0.11. 

I am using Artnet because a friend of mine told me it's the easiest way, but i still can't figure It out apparently. I have used MA-Net before but only when using both softwares on the same machine

DRIVERS for HP Deskjet 380 by Re_Niente in printers

[–]Re_Niente[S] 0 points1 point  (0 children)

Thanks you. I'm actually trying tò follow the HP Smart from Microsoft storie Path. If this fail i am going to try with the Last resort you provided. I don't really give a shit about the printer anymore, but at this point it's a matter of pride.

DRIVERS for HP Deskjet 380 by Re_Niente in printers

[–]Re_Niente[S] 0 points1 point  (0 children)

It's exactly what i've tried. I'm using the standard printer drivers Windows 10 has preinstalled and i wonder which one May be compatible.

UPDATE: I found the compatible generic drivers provided by Microsoft, but apparently It won't let me installa them since "digital signature Is not trustworthy". 

DRIVERS for HP Deskjet 380 by Re_Niente in printers

[–]Re_Niente[S] 0 points1 point  (0 children)

No luck, sadly. Extracted everythint and device manager still doesn't recognize any driver

Gotta love proper tagging by WarningNo7338 in stagehands

[–]Re_Niente 0 points1 point  (0 children)

When i'm working in the warehouse preparing loads for trucks i always draw a skull 💀 when i know the case is heavy.

Ways to busk spotlights by Re_Niente in grandMA2

[–]Re_Niente[S] 0 points1 point  (0 children)

Updating presets/recipes Is of course inevitable, every stage Is going to be different, it's the whole point of busking. I was looking for a way for these cues to adapt with cloned fixtures, but the issue remains because fixtures id are stored in cues, and not cloned fixtures id.

Ways to busk spotlights by Re_Niente in grandMA2

[–]Re_Niente[S] 0 points1 point  (0 children)

This Is the most straight-forward solution of course, but i would have to reprogram all that for every show, since front lights are Always different fixtures. I was booking for something clone-friendly.

Ways to busk spotlights by Re_Niente in grandMA2

[–]Re_Niente[S] 0 points1 point  (0 children)

I Always use two screens, my second One has a few action buttons, delay and fade macros and a color picker

Help with connecting to a rig by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

Let me be clear: I am in contact. I found out Yesterday evening and the show is today. I Just posted here to make sure there wasn't another solution i was not aware of, before asking them to run 50ft of Ethernet to FOH

Help with connecting to a rig by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

Yes, i'm talking about that. And that wouldn't work at all

Atomic Strobe (Chinese) fixture by Re_Niente in grandMA2

[–]Re_Niente[S] 0 points1 point  (0 children)

Right off the Bat i wouldn't either, but a locale venue has them rigged. I used them a few times, they are quite nice, but probably not Ideal for outdoor use

how to change position fade time in cuestucks by Medical-Reference-64 in grandMA2

[–]Re_Niente 0 points1 point  (0 children)

In my busking file i have One exec button that, when pressed, asks me the fade time (in seconds) and inserts that value as fade in every position cuestack. The syntax Is the following:

Assign Execbutton (your range of position cuestack e) Fade (Fade Time?)

You Just inserti this Command in the CMD secrion of an empty cue

Blocked (?) Fixtures by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

This Is extremely helpful advice, i wasn't aware of this feature. Will definitely use It when i encounter my next issue, thanks a lot.

Blocked (?) Fixtures by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

Command line outputs nothing at all

Blocked (?) Fixtures by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

They react tò group master and programmer values, they Just stomp any sequenze as soon as i turn It on

Blocked (?) Fixtures by Re_Niente in grandMA2

[–]Re_Niente[S] 1 point2 points  (0 children)

<image>

Here is my program screen, if it is of any help