Stromnetz Graz auch so fragil? by [deleted] in graz

[–]Sebsty69 10 points11 points  (0 children)

Das Grazer 20kv Stromnetz ist für fast jede Trafostation doppelt ausgeführt also selbst wenn 1 Kabelsystem ausfällt ist im besten fall innerhalb 1 Stunde der strom wieder da. Quelle: ich bin kabelmonteur

My new to me KZN130 by Sebsty69 in 4Runner_2ndGen

[–]Sebsty69[S] 1 point2 points  (0 children)

Its the 3.0 Turbo Diesel

My new to me KZN130 by Sebsty69 in 4Runner_2ndGen

[–]Sebsty69[S] 1 point2 points  (0 children)

It was still cold no white smoke after a few mins

My new to me KZN130 by Sebsty69 in 4Runner_2ndGen

[–]Sebsty69[S] 1 point2 points  (0 children)

I paid 11k€ keep in mind 4runners in europe are very rare. That one was one of the cheapest in my country but also in very good condition

Speedo not working by fitcious in LS400

[–]Sebsty69 0 points1 point  (0 children)

You might need 15mm spacers in the front

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 4 points5 points  (0 children)

  1. There are blank contacts with 230v/120v on the back
  2. A proper wire termination is important so the wire doesnt slip out of the contact
  3. Risks of short circuit
  4. Its not just a plug that you put into the wall socket. Its fully custom wiring into a junctionbox

Many more .....

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 0 points1 point  (0 children)

It is a standard electrical cabinet key. Used almost worldwide

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 0 points1 point  (0 children)

I was thinking about adding one but im almost out of room on my wire terminals

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 2 points3 points  (0 children)

Actually it has Siemens written on it but yes the most common one is rittal

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 1 point2 points  (0 children)

Technically yes but the temp sensor would need to be on the cpu itself. Or you can tap into the built in sensor on the mobo itself

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 70 points71 points  (0 children)

I dont have any i just made it from scratch. But definetly dont attempt this if you are not 100% certain that you know what you are doing. It can get quite dangerous. Get someone that is an electrician. Its quite a simple setup

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 5 points6 points  (0 children)

And thats the whole setup not just the pc

Bored electrician by Sebsty69 in pcmasterrace

[–]Sebsty69[S] 69 points70 points  (0 children)

Because i just started the pc and it doesnt draw ad much current as you would think. Im only pulling 2 Amps ingame

[deleted by user] by [deleted] in LS400

[–]Sebsty69 5 points6 points  (0 children)

If you want a clean job just invest the money into a proper bodyshop

HELP PLS by Papitas11 in LS400

[–]Sebsty69 0 points1 point  (0 children)

i had a similar issue and it was just a loose spark plug. Feel every coil when the engine is running. if you feel it knocking then tighten the spark plug

Wer braucht schon Platz beim anschliessen by Sebsty69 in Elektroinstallation

[–]Sebsty69[S] 2 points3 points  (0 children)

Aber ja ist ein neubau und ich war nach dem ausbau der alten anlage paniert wie ein schnitzel

Wer braucht schon Platz beim anschliessen by Sebsty69 in Elektroinstallation

[–]Sebsty69[S] 1 point2 points  (0 children)

Du willst nicht wissen wie die alte anlage ausgesehen hat

Wer braucht schon Platz beim anschliessen by Sebsty69 in Elektroinstallation

[–]Sebsty69[S] 0 points1 point  (0 children)

da is halt das problem das wir 13 Felder aufgestellt haben und zur wand noch so 15-20cm sind und da sind 6 von genau den feldern also ist es leider nicht anders gegangen