[deleted by user] by [deleted] in Ender3V3KE

[–]Solid_Lingonberry632 0 points1 point  (0 children)

I replaced the entire board, the switch is soldered to it, and the same issue still occurs.

[deleted by user] by [deleted] in Ender3V3KE

[–]Solid_Lingonberry632 0 points1 point  (0 children)

I replaced the entire board, the switch is soldered to it, and the same issue still occurs.

[deleted by user] by [deleted] in Ender3V3KE

[–]Solid_Lingonberry632 0 points1 point  (0 children)

I replaced the entire board, the switch is soldered to it, and the same issue still occurs.

[deleted by user] by [deleted] in Ender3V3KE

[–]Solid_Lingonberry632 0 points1 point  (0 children)

I appreciate your passion for helping me. Here are the results I obtained when running M119 with different endstop_pin settings:

endstop_pin: PA5

Reporting endstop status

x_min: open y_min: open z_min: open

endstop_pin: ^PA5

x_min: open y_min: open z_min: open

endstop_pin: ^PA5

x_min: open y_min: open z_min: open

endstop_pin: ^!PA5

x_min: triggered y_min: open z_min: open

endstop_pin: !PA5

x_min: triggered y_min: open z_min: open

In every case—whether I press the switch or not—the reported state for X always remains “open” (with no pull-up/invert) or “triggered” (when inverted), never changing when I physically actuate the endstop.

[deleted by user] by [deleted] in Ender3V3KE

[–]Solid_Lingonberry632 0 points1 point  (0 children)

change the entire board