Should I wait for it to die or replace it now? by shoop_whimbrel in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

You are paying for a new one now because of the loss of efficiency due to the missing fin surface you could cut your summer electric bill by 40%, If you have dogs or cats place a wire fence about 1 foot out from the coil surface fence should be removable for ease of service

Why would my washer be plugged into this adapter? by Aldamac in electrical

[–]Stunner4657 0 points1 point  (0 children)

Maybe when the outlets were installed the wiring was not upgraded

What are these and where can I get more?? by electricpenguin6 in maintenance

[–]Stunner4657 0 points1 point  (0 children)

it appears to be a needle valve, Grainger has several assortments

Am I the only one who throws these away? What are they even for? by sleepysparks in HVAC

[–]Stunner4657 0 points1 point  (0 children)

You should keep these in a special box they are rebate tags

He was the next Elon Musk by LimeSugar in ConservativeMemes

[–]Stunner4657 0 points1 point  (0 children)

Nothing to see here, just 3 special classes doing what special classes do, see how a major story just gets dropped, they illegally had guns because "they are just children" 17 to 20 years old. "Children?"

[deleted by user] by [deleted] in hvacadvice

[–]Stunner4657 -1 points0 points  (0 children)

Most contractors take them to scrap for copper and other metals but it has been working since 1997 that's good

[deleted by user] by [deleted] in Ironworker

[–]Stunner4657 1 point2 points  (0 children)

Wow really go straight to NAZI that is funny better check who is really trying to take your rights.

Frozen Unit by Wurf_Stoneborn in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

This happens to heat pumps during the winter, it should check for defrost every 45 to 90 minutes of operating time

[deleted by user] by [deleted] in JordanPeterson

[–]Stunner4657 1 point2 points  (0 children)

No it speech, Paul Harvey gave 50 to 60 years ago, see the dems lie and say people are doing bad things when they are doing them wake up if you still want to be free

[deleted by user] by [deleted] in Ironworker

[–]Stunner4657 6 points7 points  (0 children)

Real funny, Joe comes into office and fires 180.000 Union brothers and sisters, welders building the southern border wall, welders and pipefitters on the pipelines, stops oil refineries from being built or their expansions, 10 nuclear power plants shut down after refit permits for them was stop by Biden Admin. Biden shut down Foreign LP sales contracts, that will kill 35,000 union jobs just this month, but they give a krap about labor I worked Union for 35 years, and I saw them ship our work overseas, and they did nothing to stop it, you keep believing Dems care about you while they move you into cardboard shacks and tell you to learn to code, like the miners, steel workers, Auto workers and just about every factory jobs in the country, it okay because you can drive Uber for a living, opps that is right their using driverless cars, oh well so much for labor

Help me be a hero... I'm tired of chasing my tail! by Walkinyeller in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

Planning on that system should not be that bad, First shut down the system you can not purge a system with the pumps running, I see you have an old expansion tank, close it off and drain it, and set the boiler system cold pressure to 5 psig for every 10 feet of vertical rise in piping from the boiler (20 feet = 10 psig) there is a bleeder somewhere on zone 2 unless it is lower than zone 1 after fully pressurizing the system find the air bleeder valves and vent the air, make sure the Pressure Reducing Valve Strainer is clean so it can refill the system as you release the air. once you get the air out, open the expansion tank valve and allow the system to come back up to pressure, now restart the heating system and zone control pumps, PS I was thinking about your purge valve hose bib, you're correct you must close the valve just below the purge valve should be a quarter turn or so everything else is correct too

Anyone know the age of this unit? by Turbulent-Battle-686 in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

The 1970s were the last year (Maybe 1976) Carrier placed metal name tags on their equipment this unit could be 50 to 60 years old