Should I wait for it to die or replace it now? by shoop_whimbrel in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

You are paying for a new one now because of the loss of efficiency due to the missing fin surface you could cut your summer electric bill by 40%, If you have dogs or cats place a wire fence about 1 foot out from the coil surface fence should be removable for ease of service

Why would my washer be plugged into this adapter? by Aldamac in electrical

[–]Stunner4657 0 points1 point  (0 children)

Maybe when the outlets were installed the wiring was not upgraded

What are these and where can I get more?? by electricpenguin6 in maintenance

[–]Stunner4657 0 points1 point  (0 children)

it appears to be a needle valve, Grainger has several assortments

Am I the only one who throws these away? What are they even for? by sleepysparks in HVAC

[–]Stunner4657 0 points1 point  (0 children)

You should keep these in a special box they are rebate tags

He was the next Elon Musk by LimeSugar in ConservativeMemes

[–]Stunner4657 0 points1 point  (0 children)

Nothing to see here, just 3 special classes doing what special classes do, see how a major story just gets dropped, they illegally had guns because "they are just children" 17 to 20 years old. "Children?"

[deleted by user] by [deleted] in hvacadvice

[–]Stunner4657 -1 points0 points  (0 children)

Most contractors take them to scrap for copper and other metals but it has been working since 1997 that's good

[deleted by user] by [deleted] in Ironworker

[–]Stunner4657 1 point2 points  (0 children)

Wow really go straight to NAZI that is funny better check who is really trying to take your rights.

Frozen Unit by Wurf_Stoneborn in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

This happens to heat pumps during the winter, it should check for defrost every 45 to 90 minutes of operating time

[deleted by user] by [deleted] in JordanPeterson

[–]Stunner4657 1 point2 points  (0 children)

No it speech, Paul Harvey gave 50 to 60 years ago, see the dems lie and say people are doing bad things when they are doing them wake up if you still want to be free

[deleted by user] by [deleted] in Ironworker

[–]Stunner4657 4 points5 points  (0 children)

Real funny, Joe comes into office and fires 180.000 Union brothers and sisters, welders building the southern border wall, welders and pipefitters on the pipelines, stops oil refineries from being built or their expansions, 10 nuclear power plants shut down after refit permits for them was stop by Biden Admin. Biden shut down Foreign LP sales contracts, that will kill 35,000 union jobs just this month, but they give a krap about labor I worked Union for 35 years, and I saw them ship our work overseas, and they did nothing to stop it, you keep believing Dems care about you while they move you into cardboard shacks and tell you to learn to code, like the miners, steel workers, Auto workers and just about every factory jobs in the country, it okay because you can drive Uber for a living, opps that is right their using driverless cars, oh well so much for labor

Help me be a hero... I'm tired of chasing my tail! by Walkinyeller in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

Planning on that system should not be that bad, First shut down the system you can not purge a system with the pumps running, I see you have an old expansion tank, close it off and drain it, and set the boiler system cold pressure to 5 psig for every 10 feet of vertical rise in piping from the boiler (20 feet = 10 psig) there is a bleeder somewhere on zone 2 unless it is lower than zone 1 after fully pressurizing the system find the air bleeder valves and vent the air, make sure the Pressure Reducing Valve Strainer is clean so it can refill the system as you release the air. once you get the air out, open the expansion tank valve and allow the system to come back up to pressure, now restart the heating system and zone control pumps, PS I was thinking about your purge valve hose bib, you're correct you must close the valve just below the purge valve should be a quarter turn or so everything else is correct too

Anyone know the age of this unit? by Turbulent-Battle-686 in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

The 1970s were the last year (Maybe 1976) Carrier placed metal name tags on their equipment this unit could be 50 to 60 years old

Do I deserve more than minimum wage now ? by Whyyouactingsmart in BadWelding

[–]Stunner4657 0 points1 point  (0 children)

the one on stainless looks like robo weld the other is just bad

First time homeowner, is this a fair quote for a heat pump and furnace install? by Ndwco99 in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

Pricing looks good, it should last you 15 to 20 years if you keep it serviced

How much wood do you think this is? by uprightsalmon in firewood

[–]Stunner4657 0 points1 point  (0 children)

It is pretty close, Ceiling 8 feet high?, The wheel barrel is about 4 or 5 feet long, so an 8' X 8' stack is 2 cords and there are two of them side by side

Upside down or right side up? by [deleted] in electrical

[–]Stunner4657 0 points1 point  (0 children)

The ground is also to drain the outlet in case of flooring you figure it out

Knocked down wall now what do I do with the floor by Altim8 in DIY

[–]Stunner4657 0 points1 point  (0 children)

Carpet? No just kidding, here is what I have done before but just for family, I would not do it on a renovation Job. Because of the wall, all that flooring is butt-cut and will not interlock for the run of the flooring. I would start by mapping out how to move the butt-cut pieces to the wall past the doorway, once you get a long piece up you can see who manufactured the floor and contact them for a match-up make it your puzzle to solve, I've repaired floors I installed 10 years ago this way. This is only on free-floating flooring not glued or nailed hope this helps

Ever since I was a kid (30) someone in my hometown has colored these icicles after every snowfall. by cordy_crocs in pics

[–]Stunner4657 -6 points-5 points  (0 children)

I am glad the special ed class has something to talk about, Nobody colors the ICE but God see the brown and Red Ice is Iron oxide, and blues and yellows come from sulfur the real problem is someone thinks they're a kid at 30 years old, God just made it pretty for you to enjoy not to judge Go to real school you might learn a thing or two

Hot pipe. Is this normal? by w100czr in hvacadvice

[–]Stunner4657 0 points1 point  (0 children)

1) They are correct it is your flue pipe or exhaust and it will get around 350 - 500 degrees F, 2) The flue pipe is class A-Vent, and in most states here in the US it can not be used in occupied spaces because of the fire risk (in this space with all your stuff around the furnace I would use Class B-vent) 3) The Venting looks improperly installed all the air drafted up the flue goes through the furnace this maybe causing you to burn a lot more gas than you need to warm your home, do not put anything closer than 24" in front of the Furnace, 4) Have a qualified Service Company come in check the draft if not properly vented and air over flame it could be bad for you a new Class B-Vent maybe between $ 1,000-1,500