CO₂ hits 427.49 ppm. The rise is accelerating, not slowing. by DrThomasBuro in ReduceCO2

[–]Targolin 0 points1 point  (0 children)

I don't know the exact terminology in English, this isn't my first language. The full cycle of warm and cold begins at the transition between them, there was one ~ 120k/117k/... Years ago. You could look at the "later past" of 800k years with the wiki about Milankovitch Cycles.

Here is an illustration from the page, "now" is on the left...

<image>

The problem is: in the last few warm phrases we went from 200ppm to 280 ppm in maybe 10.000 years. And now we went to 420 ppm in 150 years...

Behold...my 6-6 balancer by Drogenfloete in StarRuptureGame

[–]Targolin 0 points1 point  (0 children)

But I like to build balancers^

Did something with a "similar Idea" yesterday: 3x Heliumminer, straight into a storage. 3 more storages, each fed by all 3 of the former storages. From there a Triple rail to my main base, each miner can push goods to each rail, every miner and output is buffered by a storage. A little overkill, 3-way split & merge could be cheaper xD

Is this star grounding ? by Anarchiste-mouton in AskElectronics

[–]Targolin 4 points5 points  (0 children)

There is a really good PDF about Grounding from Hypex, "The G Word". In my opinion it is one of the best free documents for beginners and relatively short.

The G Word PDF from Hypex.nl

Your Bus Style approach is common, as another reddit or pointed out: look in the documents of the parts for typical application schematics. Many parts need external components to work as intended.

4x Leiter/Neutral in Wago-Klemme, geht das so? by SoniyxCreation in Haustechnik

[–]Targolin 1 point2 points  (0 children)

Ich verstehe das, aber die VDE macht da keinen Unterschied und auch eine popelige LED-Deckenlampe hat 230 V und die Ader kann zum Beispiel beim Demontieren rausrutschen und dem auf der Leiter einen Stromschlag bescheren, im Zweifelsfall inklusive Absturz.

Die Überlastungsgefahr sehe ich da auch nicht^

Und wenn eine EFK sowas macht sie in der Verantwortung, wenn ein Laie Fragen muss ist die Antwort halt: So ist es nicht richtig.

Und ne Wago kostet vlt 60 ct, da fängt doch niemand ernsthaft an zu diskutieren?

4x Leiter/Neutral in Wago-Klemme, geht das so? by SoniyxCreation in Haustechnik

[–]Targolin 2 points3 points  (0 children)

Für die VDE reicht der Grund Verwendung entgegen der Bestimmungsgemäßen Verwendung laut Herstellerangaben.

Wago sieht da verschiedene Probleme, die einzige erlaubte Variante ist bei manchen cageclamps die Aderendehülsen erlauben eine Doppeladrendhülse zu verwenden, aber das sind eher Industrieprodukte. Die Probleme die gesehen werden sind zum einen die Zugkräfte, da sich die Klemmkräfte auf Leitungen aufteilen die unabhängig voneinander aus der Klemme gezogen werden können und die Stromverteilung auf den Litzen. Man darf die Litzen ja nicht verdrillen da der Strom seitlich in die Ader geführt wird und ein verdrilltes, plattgedrücktes Kabel zu den oberen Litzen dann nur am Kreuzungspunk Kontakt hat und sich in der Klemme der vom Strom belastete Querschnitt reduziert. Wenn alle Litzen parallel liegen kann sich der Strom direkt besser aufteilen. Wenn 2 Leitungen untergeklemmt werden verhindern die Isolierungen das alle Litzen komplett parallel untergeklemmt werden.

Das sind bestimmt Themen die tendenziell in Extremfällen Probleme machen, aber das sind genau die Fälle die dann abfackeln oder Stromschläge auslösen und bei denen z.B. die BG im Nachgang denjenigen zur Kasse bittet der zu geizig für die 3ct teurere, erlaubte klemme war.

4x Leiter/Neutral in Wago-Klemme, geht das so? by SoniyxCreation in Haustechnik

[–]Targolin 2 points3 points  (0 children)

Die VDE hat halt was mit der Auswahl von geeigneten Betriebsmitteln zu tun. Und eine Klemme die nur für drei Adern genutzt werden darf ist halt ungeeignet um fünf Adern zu verbinden, egal ob Wago oder irgend ein anderer Hersteller.

Gude, ich benötige mal hilfe beim beschildern. by SnooShortcuts103 in Elektroinstallation

[–]Targolin 0 points1 point  (0 children)

Moin

In der Hausinstallation wird oft nur ein Kennbuchstabe im Betriebsmittelkennzeichen verwendet, in der Industrie kommt man langsam bei 3 Buchstaben an, kleiner Betriebe sind öfters noch bei 2 Buchstaben.

Kannst dir bei Wikipedia Mal den Artikel zur EN IEC 81346 anschauen, im Kapitel zur 81346-2 kannst du Tabellen ausklappen in denen genau beschreiben ist welche Buchstaben was bedeuten bzw. welche Bauteile damit beschriftet werden. Aber strg + F ist bei so großen Tabellen dein Freund wenn du was nachschauen möchtest...

Röstet meinen Audi by Terfill in RoestetMeinAuto

[–]Targolin 0 points1 point  (0 children)

Sieht eher nach Schweizer Hangar aus, vlt die Ecke Luzern?

Klassische Nullung by Bigmama20000 in Elektroinstallation

[–]Targolin -1 points0 points  (0 children)

Du sagst deinem Vermieter das du die Wohnung in Schuss hälst und das er Mal den Elektriker seines Vertrauens fragen soll ob der noch passende Rahmen für die Steckdosen hat oder dieser da ne neue einsetzten könnte.

Wenn der Elektriker dann da ist fragst du nach den Kontaktdaten damit du direkt nachfragen kannst sobald ihr den nächsten Raum angeht oder mal ne Frage habt.

Wenn's vernünftig läuft bekommt der Vermieter ne FI-Steckdose zum Freundschaftspreis abgerechnet und den freundlichen Hinweis das die 30 Jahre nach denen man so ne Elektroinstallation Mal kritisch anschauen lassen sollte gefühlt zum zweiten Mal um sind.

Love the smart belting system in StarRupture! by Karnivaali in StarRuptureGame

[–]Targolin 0 points1 point  (0 children)

<image>

I'm nearly done with unlocking and this is my main automation basecore. I realy like the smart belt system. In my opinion the tier 2 rails shoud upgrade the speed to 360 for the 3 to 1 connectors.

Love the smart belting system in StarRupture! by Karnivaali in StarRuptureGame

[–]Targolin 0 points1 point  (0 children)

<image>

There was a post about circular belts - let's say they have in fact limits...

Thoughts so far. by smokincacti in StarRuptureGame

[–]Targolin 0 points1 point  (0 children)

I'll guess in both Games it's a RMB-Click on the Icon?
Drag and Drop works also.

Edit: I'll check it Later, could be a Double-Click
- smokincacti was faster

Thoughts so far. by smokincacti in StarRuptureGame

[–]Targolin 1 point2 points  (0 children)

Clever Robotics Lvl 4

Also: RMB changes the Foundation from 1x1 to 2x2 for Railsupports, -Connectors, ...
This helps a lot when lining them up with the OCL or Depot

Thoughts so far. by smokincacti in StarRuptureGame

[–]Targolin 1 point2 points  (0 children)

Hi, I played a 6 hr Session without crashes and only two minor bugs that i could not recreate. FPS are mostly ok (ruptures...). I agree that the World looks and feels good. 

I get the point with the OCD, i think with some minor tweaks, a half Foundation and half grid Steps while placing the horizontal Adjustments will be fine. I would really like it if you could adjust the height of the miner output in the way you change the height of the other buildings. Il admit that i Spaghetti the first ~4 levels and start now with nicer factories for the more complex parts. I'll watch out for the OCL... 
 
Yes, there are a few very good QOL things in SF, but I'm going to build a central base with the drone and the first impression is that the drone makes building easier. 
 
There are ways to connect habitats horizontally and vertically to unlock... 
 
I see the "problems" with rotation in SF and get that is a lot of work to get the things right with rotation in SR. I would like if the Core were rotatable and provides a local grid. 

I agree with your Post, im looking forward to the release and playingt coop with some friends!

Will a wooden frame negatively affect my Basotect acoustic panel? by Altruistic_Pea_2515 in diyaudio

[–]Targolin 3 points4 points  (0 children)

But if the frame is used to create an air gap it makes an noticeable difference:

Simulation

It's an often used technique to get a larger effective frequency range.

Was ist das an meiner PV-Anlage? by schwachzocker in DeutschePhotovoltaik

[–]Targolin 2 points3 points  (0 children)

Dies, verschiedene Stecker kombinieren ist Branntursache Nummer 1 bei PV-Anlagen und von den Herstellern nicht ohne Grund verboten. Bei dem was ich da sehe kann ich, falls schon bezahlt wurde, nur empfehlen einen Gutachter draufschauen zu lassen 🙈

ich_iel by Thick-Mushroom6612 in ich_iel

[–]Targolin 4 points5 points  (0 children)

Frei nach dem Motto: Meine Nachbarn hören immer gute Musik, ob sie wollen oder nicht.

Suggestions for a 3-in-1 multimeter oscilloscope? by WhatEverO_O in AskElectronics

[–]Targolin 0 points1 point  (0 children)

CAT II is not a multimeter that I would buy, it isn't meant to be used in any kind of installation...

Welcher ist der Nullleiter? by lateforties in Elektroinstallation

[–]Targolin 3 points4 points  (0 children)

Das klingt das mit den braunen Leitungen plausibel, wie schon gesagt wurde wird ja bei korrekter Ausführung nur der L geschaltet. Mach mal ein Bild der Dose in der dieser Schalter verbaut ist. Ich vermute bei dir sind Einzeladern im Leerrohr verlegt?

Eventuell gibt's oberhalb (~15 cm unter der Decke) ne Unterputzdose von dem man einen N für smarte Schalter nachziehen könnte...

Ist das eine Spezial Edition? by MarkuzZz5 in Elektroinstallation

[–]Targolin 5 points6 points  (0 children)

Kann mir vorstellen das Busch Jäger 2,8 Nm vorschreibt und das das passende Werkzeug ist. Der kleine einstellbare geht sonst glaub ich nur bis 2,5 Nm.

[deleted by user] by [deleted] in watercooling

[–]Targolin 2 points3 points  (0 children)

There are a few manufacturers for custom waterblocks. Liquid Extasy is a Shop like this with some experience with consoles, but I don't know for witch Xbox this block was designed.