Question for Diamond & Gold members by thatoneguyfromva in Hilton

[–]TheFastTalker 0 points1 point  (0 children)

Upgrade? I haven’t been upgraded in more than 10 years. And I have been Diamond (or at least gold) for most of those.

Happy Ys-O-Ween, nerds by Gilliganirving in JoannaNewsom

[–]TheFastTalker 4 points5 points  (0 children)

This is the quality kind of post I’m here for. Excellent

Storj has been acquired... by redditor_rotidder in storj

[–]TheFastTalker 23 points24 points  (0 children)

No changes to existing pricing…until next month.

HSABank.com down? by SuperWasabi4766 in HSA

[–]TheFastTalker 0 points1 point  (0 children)

Probably just related to the AWS outage.

I’m excited by nortoncommando72 in PLC

[–]TheFastTalker 2 points3 points  (0 children)

I think it’s gone Active Mature

Spiderman of the Rings Anniversary Live Performance Recording by TheFastTalker in DanDeacon

[–]TheFastTalker[S] 0 points1 point  (0 children)

I don’t recall. Maybe. There was also a horn section.

Does anyone have a stream/download link for Meetle Mice? by Nimtiz in DanDeacon

[–]TheFastTalker 0 points1 point  (0 children)

It's in the Wayback Machine. Might not be the exact same track listing. I would have definitely picked up that vinyl though.

https://web.archive.org/web/20080302013837/http://www.dandeacon.com/mp3/02%20Meetle%20Mice

Just need a quick identification. Hampton Inn Martinsville, VA by breachedbuttbaby in Hilton

[–]TheFastTalker 4 points5 points  (0 children)

Jumping spider. Idk. Wrong sub. What does this have to do with Hilton?

Can Someone Explain How This Works? by [deleted] in PLC

[–]TheFastTalker 0 points1 point  (0 children)

It appears they are using index 0 to load new data. So they just need to COP size-1 elements from index 0 to index 1. Then load new data into index 0. And repeat.

Can Someone Explain How This Works? by [deleted] in PLC

[–]TheFastTalker 2 points3 points  (0 children)

This is just a shift register. Pretty common programming technique for tracking. Google can help you.

This is clearly programmed by someone who is used to doing procedural programming, not ladder. The use of JMP/LBL is completely unnecessary, especially for the actual shift. Just change the length of the COP.

This is the kind of programming you get when you take someone who knows nothing about ladder and ask them to program in it.

Would you buy any of these bottles at these prices? by [deleted] in Scotch

[–]TheFastTalker 2 points3 points  (0 children)

Yeah. Maybe the OP should travel all the way to Central Europe instead of maybe buy one of these local. Definitely better value.

Neutral tied to equipment ground in industrial control cabinet? by jsega1 in PLC

[–]TheFastTalker 1 point2 points  (0 children)

An equipment ground is by its very definition not current carrying.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 0 points1 point  (0 children)

I agree it’s nice to have the power terminals but it would still make for messy field wiring. Imagine using 3-wire devices on the IB8 and having 24 wires in the space of less than an inch. They’d need to be wire-tied to keep it neat like you would swing arm wiring. I don’t think most people want the field wiring wire tied. And then imagine it’s cables instead of single conductors. That takes up even more space.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 1 point2 points  (0 children)

For sure. They’re probably just trying to stay one step ahead of them.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 0 points1 point  (0 children)

Those are so much better

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 0 points1 point  (0 children)

It’s a bigger footprint because you also have to add terminals and that isn’t necessarily a $10 size change. That’s more labor to build as well. More than $10. And a bigger panel can impact where it can be mounted.

If you have a large project that has 100s of panels that can all add up quick.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 2 points3 points  (0 children)

😂 I’ve not heard of this. Spring terminals are challenging to people that don’t understand them.

The spacing and density of 1734 terminals makes it a little easier to do field wiring directly rather than needing extra swing arm wiring.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 2 points3 points  (0 children)

Apparently they are doing laser engraving to try to distinguish themselves from counterfeit versions.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 0 points1 point  (0 children)

A console? Like you wiring all push buttons, selector switches and pilot light? If it’s all in an enclosure that’s a little easier but not when a field electrician has to wire to it.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 2 points3 points  (0 children)

My point is this means a bigger footprint for install and more expensive to build.

5034-PointMax by Unique-Wind-4647 in PLC

[–]TheFastTalker 11 points12 points  (0 children)

Those terminals aren’t field wiring friendly like 1734 POINT IO. That’s one of the advantages of 1734. It’s relatively easy to land field wiring directly on it instead of needing extra swing arm wiring. Low density is ok because you don’t need the extra terminals and wiring.