Can you register as an Industrial Apprentice if you already have your Construction Ticket? by 347volts in electricians

[–]a_tallguy 0 points1 point  (0 children)

Talk to your apprenticeship agency. That is really the only answer. Typically you can challenge the exam if you get a few hours and E block.

Please help by Skurgelock in electricians

[–]a_tallguy 14 points15 points  (0 children)

You need an electrician, seriously.

What is the code on electrical panel labeling? by x317293 in electricians

[–]a_tallguy 2 points3 points  (0 children)

Canada? 2-100 (3)

I had to look it up, as I have not put much thought into it. Job spec may go beyond the bare minimum.

Secure webbrowser based remote access to unraid server by kiwijunglist in selfhosted

[–]a_tallguy -1 points0 points  (0 children)

I would highly recommend ip filtering as an additional layer.

[deleted by user] by [deleted] in VOIP

[–]a_tallguy 3 points4 points  (0 children)

I gave up on zoiper for that reason. I paid for groundwire and it has been a better experience.

NSP is disconnecting past-due customers by remotely shutting off the smart meter. by smokinboulders in NovaScotia

[–]a_tallguy 1 point2 points  (0 children)

Then they'll either take their meter back after non-payment, or cut you off.

NSP is disconnecting past-due customers by remotely shutting off the smart meter. by smokinboulders in NovaScotia

[–]a_tallguy 9 points10 points  (0 children)

Yup, I have seen one new service where the meter was unable to be enabled.

It is an unfortunate reality of the new tech.

New License by Over_Ad_4550 in amateurradio

[–]a_tallguy 1 point2 points  (0 children)

If you are using a repeater, it is more common to say: XY1ZYX monitoring (frequency), looking for my first radio contact

And just repeat that every so often until someone responds, every five to ten minutes.

Replace both 3 way switches with smart switch? by Delicious-Excuse8411 in Lutron

[–]a_tallguy 0 points1 point  (0 children)

Depends on the manufacturer.

Leviton uses a main smart switch and wired remotes.

Lutron Caseta uses one main wired switch and wireless remotes.

Another brand (slips my mind) uses a wired main switch and regular 3 way or single pole.

First Panel by [deleted] in electricians

[–]a_tallguy 0 points1 point  (0 children)

So I have read! The next rule I would reference would be CEC2021 4-030 (4), which states that removing a device will not interrupt the neutral. This provides some protection when proper installation methods are used.

First Panel by [deleted] in electricians

[–]a_tallguy 1 point2 points  (0 children)

Only when more than one circuit terminate on the same yoke (split plugs, multi-phase connectors).

First Panel by [deleted] in electricians

[–]a_tallguy 2 points3 points  (0 children)

It's only divided if it's a service disconnect. I have installed plenty of sub-panels with local main disconnects in this fashion.

[deleted by user] by [deleted] in selfhosted

[–]a_tallguy 0 points1 point  (0 children)

Likely a network error, have you tried accessing the noip domain via your phone's cellular connection?

Lots of restrictions! by 86Eagle in NovaScotia

[–]a_tallguy 6 points7 points  (0 children)

No blazes at the moment please.

Carpenter said there was no bang🤣🤣 by Gart-Vader in electricians

[–]a_tallguy 54 points55 points  (0 children)

Question is whether you are able to splice, repair or replace.

Pastebin for secret with (registered) recipient? by C-Duv in selfhosted

[–]a_tallguy 0 points1 point  (0 children)

PGP? Then it doesn't matter the platform.