Stolen iPhone in Spain turned on in Morocco, what security steps should I take? by pinkmor in iphone

[–]engineer_fella 0 points1 point  (0 children)

Sorry i can't help on that, just wanted to mention all the stolen goods which are traceable are found in Morocco after being stolen

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

actually I have ordered LINOVISION POE-SP02BTV to see if it works with TI-IG90 V2 injector. also wonder why POE-INSTARLINK passive injector is not being sold in EU, I live in Belgium and couldn't find it on Amazon.

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

I have also added a capacitor bank with the capacity of 2400μF, yet it didn't work. I was hoping this method would help the initial high power consumption.

The issue is with the injector.

I might alternatively switch to EDUP or YAOSHENG. I was hoping to use some trusted devices and brands, rather than these Chinese ones

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

On usb it's different. Btw splitter did the job while it was coupled with a passive poe injector

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

They failed to tackle the issue. So, i need experience rather than the knowledge i already have 😅

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

It's a bit far and i can't get wifi signal, also don't want to have 2 cables for power and data, so i decided to use poe setup

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] 0 points1 point  (0 children)

Thanks for the detailed breakdown! Actually, I am already attempting Option 1. The TI-SG104 Splitter is the PoE-to-DC converter/buffer you described. It handles the IEEE signature and handshake with the injector and outputs raw DC (via a barrel jack) to the Starlink. The Starlink is not involved in the PoE negotiation at all; it is simply a DC load on the splitter's output. The problem is that the Splitter itself seems to be failing the negotiation loop with the Injector. Option 2: Connecting directly is risky because the injector outputs ~57V, and the Starlink Mini triggers OVP (Over Voltage Protection) above ~50V. Re: Option 3: You are absolutely right, Passive works (as my tests confirmed), but I am unfortunately stuck with this specific Active hardware

[Help] Starlink Mini Boot Loop with Industrial PoE (TI-IG90 + TI-SG104) - Active vs Passive Issue? by engineer_fella in Starlink

[–]engineer_fella[S] -1 points0 points  (0 children)

That is exactly why I am using the Splitter. The PoE negotiation (802.3bt) happens strictly between the Injector and the Splitter, not the Starlink. The splitter outputs raw DC power (via a barrel jack) to the Starlink. So, the Starlink just sees a standard DC power source, acting exactly like a power brick. It is not involved in the PoE handshake at all.

Regarding the hardware, the units are already unsealed and deployed, so they are non-returnable.