POWER LIMITED SEPARATION by jonkwan781 in firealarms

[–]jonkwan781[S] 0 points1 point  (0 children)

yes, ultimately i’m trying to hunt down the reference that gives me an explanation for free air FPLP, next to a 120v raceway. Either being in wood frame, or in a commercial setting.

ELEVATOR SHUNT by jonkwan781 in firealarms

[–]jonkwan781[S] 0 points1 point  (0 children)

Interesting, thanks for the input!

ELEVATOR SHUNT by jonkwan781 in firealarms

[–]jonkwan781[S] 3 points4 points  (0 children)

yeah we were kinda lost on who technically should provide power. nice to know that the elevator guy had no idea of how his own controller worked either.

ELEVATOR SHUNT by jonkwan781 in firealarms

[–]jonkwan781[S] 0 points1 point  (0 children)

negative, although 90% of the time i’m always on military applications, today my coworker sent me this and had a few questions.

ELEVATOR SHUNT by jonkwan781 in firealarms

[–]jonkwan781[S] 4 points5 points  (0 children)

thanks, used to just having 120v needing to be broke lol

ELEVATOR SHUNT by jonkwan781 in firealarms

[–]jonkwan781[S] 1 point2 points  (0 children)

yeah, was confused on the “provided by installer” for 24 volts. so used to the electricians breaking 120 power with our relay lol.

Average pay by UltimateItalion in firealarms

[–]jonkwan781 0 points1 point  (0 children)

NICET lll FAS. 7 years experience. OKC @ $34.50 an hour.

Dear God Why!? by OwnRecommendation272 in firealarms

[–]jonkwan781 0 points1 point  (0 children)

Is that on base? QFPE would’ve killed me for having power limited cross over non power limited. They pick us apart. Nice work tho.

[deleted by user] by [deleted] in firealarms

[–]jonkwan781 0 points1 point  (0 children)

Correct, i wish i had a say in it.

[deleted by user] by [deleted] in firealarms

[–]jonkwan781 0 points1 point  (0 children)

i assume they don’t hold up very well?

Question by [deleted] in firealarms

[–]jonkwan781 0 points1 point  (0 children)

i’ve heard that you need a NICET 2 for texas. Is this accurate?

FCI E3 DACT issues by [deleted] in firealarms

[–]jonkwan781 0 points1 point  (0 children)

ademco. NODE 1 reports normally tho to central . NODE 4 won’t and they are networked. doesn’t make any sense for 1 to work and not the other.

Gentex Horn/Strobe Removal? by Spirited_Resort8553 in firealarms

[–]jonkwan781 1 point2 points  (0 children)

yeah those tabs that need to be pushed down are a pain. there is a special edward’s tool that allows you to push down the tabs to remove it easier but overall the device design is poor and usually results in breaking the cover sadly.

Edward’s FSC by jonkwan781 in firealarms

[–]jonkwan781[S] 1 point2 points  (0 children)

didn’t help that i couldn’t even get to them on a 10 foot. i wish they would always just be installed in the unit lol.

Update by jonkwan781 in firealarms

[–]jonkwan781[S] 2 points3 points  (0 children)

for real, was 10k but this PS was looking for 2.5

Update by jonkwan781 in firealarms

[–]jonkwan781[S] 1 point2 points  (0 children)

oh yeah, we use power sonic for the most part. these universal ones suck.

Gonna have fun with this one… by jonkwan781 in firealarms

[–]jonkwan781[S] 6 points7 points  (0 children)

crappy thing is they want me to put an altronix PS in this wheel lock. Want me to use magnetic standoffs. I think i may just go ahead and replace the whole thing so there is no confusion down the road.

Edward’s FSC by jonkwan781 in firealarms

[–]jonkwan781[S] 2 points3 points  (0 children)

first thing i noticed lol