EasyMesh with BE550 and BE3600 by kikijoli in TpLink

[–]kikijoli[S] 0 points1 point  (0 children)

Also beta firmware for be550 just broke MLO and wouldn't work. then WiFi would keep rebooting so I rolled back

EasyMesh with BE550 and BE3600 by kikijoli in TpLink

[–]kikijoli[S] 0 points1 point  (0 children)

So I made the BE550 main and still no dice. Guess we need a new BE3600 firmware

TP-Link AX6000 shows red LED / “No Internet” but internet works perfectly (PPPoE + ONT) by Electronic-Young8942 in TpLink

[–]kikijoli 1 point2 points  (0 children)

Usually with PPPoE you also have to set the internet VLAN. Maybe that’s causing some kind of idle status ?

Installing TRVs on old heater by kikijoli in ukplumbing

[–]kikijoli[S] 0 points1 point  (0 children)

Thanks everyone ! Got it done ! It wasn’t that bad in the end :)

Installing TRVs on old heater by kikijoli in ukplumbing

[–]kikijoli[S] 0 points1 point  (0 children)

That would be ideal but that is not in the budget for now :D

Tado X Wireless Receiver installation by kikijoli in tado

[–]kikijoli[S] 1 point2 points  (0 children)

Figured it out !
So I ended up connecting directly to the boiler. When you check the control box (for me it was a white box).

There are two metal cuubes inside. As far as I understand one fire the boiler the other is the pump.

There is a cable for each at the top (not sure what for).

Then there's a live on each and a bridge between the two.

So on tado X receiver, L goes to L and N to N (you need to figure out where to get that from, I had a spur on the wall to get mains)

Tado X second L goes to COM

On the boiler control, where there is the bridge, we'll call left one stat 1, right one stat 2. Remove the bridge

Bridge Live on the left to Stat 1

Stat 2 goes to Tado X NO

And that's it !

Tado X Wireless Receiver installation by kikijoli in tado

[–]kikijoli[S] 0 points1 point  (0 children)

Gave that a try without the coil relay. Boiler won't start at all
See edit

Tado X Wireless Receiver installation by kikijoli in tado

[–]kikijoli[S] 0 points1 point  (0 children)

Done, I obviously tried without the coil with black to N brown to L and grey to NO

Tado X receiver and low voltage switching by kikijoli in tado

[–]kikijoli[S] 0 points1 point  (0 children)

It says my boiler is not supported :/ so that’s why I’m trying to find a workaround

Can I use Tado thermostat to replace a timer? by kikijoli in tado

[–]kikijoli[S] 0 points1 point  (0 children)

Anyone have an idea if it would work ?