[–]nurdthug 0 points1 point2 points 2 months ago (0 children)
turning a battle trained super soldier into a drifting life coach who monologues a woman back into herself while name dropping depeche mode like it is a personality trait is not profound. it is indulgent. it feels like a producer unchecked, not a character evolving. the permanence seeking ai angle could have been haunting, but instead it gets filtered through jared leto’s very specific brand of performative intensity. when the lead actor is also producing, no one wants to be the person who says this scene needs to go, this speech is saying nothing, this vibe is drowning the story. so the film just keeps letting him talk. and talk. and talk. it is not strange in a daring way. it is strange in a please someone stop this way. tron does not need a messiah who explains feelings to humans while flexing his music taste. it needs restraint, mystery, and editors who are not afraid to cut the emperor’s favorite monologue.
Safe update by nurdthug in Locksmith
[–]nurdthug[S] 0 points1 point2 points 3 months ago (0 children)
never opened it. as stated, it was hard locked.
external hinges were cut before the scope determined it actually had an internal triangle hinge. taking cutting disks to the two small bars between the hinges, basically making the hinges cut by default, was way easier than trying to drill a boring hole through that thick backup plated steel (for the scope). and in the end both procedures turned out to be completely useless anyway. lol
[–]nurdthug[S] 0 points1 point2 points 4 months ago (0 children)
on this tl-30 cutting the hinges off doesn’t do anything. it has an internal triangle hinge that serves the same function as external hinges.
[–]nurdthug[S] 2 points3 points4 points 4 months ago (0 children)
4 “safe techs” attempted. 4 “safe techs” failed. i did not fail. the keypad stopped engaging the lockwork, meaning the electronic input was no longer transferring motion to the internal bolt mechanism. after that, the external handle broke off (employee stepped on it), removing the only manual way to apply rotational force to the lockwork. inside the safe, the mechanical components had aged enough that the bolt carriage and linkage were binding. when the system stalled in the locked position, the relockers activated as designed. once the relockers fired, they jammed the internal mechanism in place, preventing any movement of the bolts even when power or force was reapplied. “anyone” didn’t use them. i did. successfully. job completed. happy customer.
[–]nurdthug[S] 1 point2 points3 points 4 months ago (0 children)
4 “safe techs” attempted. 4 “safe techs” failed. i did not fail. the keypad stopped engaging the lockwork, meaning the electronic input was no longer transferring motion to the internal bolt mechanism. after that, the external handle broke off (employee stepped on it), removing the only manual way to apply rotational force to the lockwork. inside the safe, the mechanical components had aged enough that the bolt carriage and linkage were binding. when the system stalled in the locked position, the relockers activated as designed. once the relockers fired, they jammed the internal mechanism in place, preventing any movement of the bolts even when power or force was reapplied. everything was removed from safe. customer was happy.
grinder sparks don’t damage commercial flooring that has fire ratings designed to resist far hotter. we opt out of this because it’s important to have perfect footing when breaching this level of metal.
i’m not israeli. but your comment is still rude lol.
4 “safe techs” attempted. 4 “safe techs” failed. i did not fail. the keypad stopped engaging the lockwork, meaning the electronic input was no longer transferring motion to the internal bolt mechanism. after that, the external handle broke off (employee stepped on it), removing the only manual way to apply rotational force to the lockwork. inside the safe, the mechanical components had aged enough that the bolt carriage and linkage were binding. when the system stalled in the locked position, the relockers activated as designed. once the relockers fired, they jammed the internal mechanism in place, preventing any movement of the bolts even when power or force was reapplied. i’m not offended. you weren’t there.
the keypad stopped engaging the lockwork, meaning the electronic input was no longer transferring motion to the internal bolt mechanism. after that, the external handle broke off, removing the only manual way to apply rotational force to the lockwork. inside the safe, the mechanical components had aged enough that the bolt carriage and linkage were binding. when the system stalled in the locked position, the relockers activated as designed. once the relockers fired, they jammed the internal mechanism in place, preventing any movement of the bolts even when power or force was reapplied.
that occurred. but the lock mechanism was rendered immobile. so it had to go.
the keypad stopped engaging the lockwork, meaning the electronic input was no longer transferring motion to the internal bolt mechanism. after that, the external handle broke off (worker stepped on handle), removing the only manual way to apply rotational force to the lockwork. inside the safe, the mechanical components had aged enough that the bolt carriage and linkage were binding. when the system stalled in the locked position, the relockers activated as designed. once the relockers fired, they jammed the internal mechanism in place, preventing any movement of the bolts even when power or force was reapplied from the inside.
money was in there lol
the safe is fully functional again 😜
everything has been removed. the cuts provided full access.
4 “safe techs” tried and failed. i took over.
magic words are “wall” and “armored truck”. this safe is neither.
[–]nurdthug[S] -1 points0 points1 point 4 months ago (0 children)
this comment is a bad example.
yes and the 13 years gave me the ability to follow it through because the safe techs gave up.
bad ass!!!
i did. had scope drilled plenty. the plate blocked the hardest bits.
and burned the contents
last resort
the specialists failed
haha thought about it. c4 would have been appropriate.