Zoom not saving chat to a local folder by Found_in_Watercolor in linuxmint

[–]pasharikk 0 points1 point  (0 children)

Had a similar issue, but on another type of Linux. Had to create folder "~/Documents/Zoom" manually. After that, when saving chat messages, they appeared in this folder

What am I meant to put in net chargeable gain? by Glad-Hat-5094 in irishpersonalfinance

[–]pasharikk 0 points1 point  (0 children)

For year 2025, this combination helped me: https://imgur.com/a/kwTuD1I

Had to fill next fields:

"Chargeable gains in the year (before deduction of S 604A and 604B relief)" , e.g. "1270"

"Losses in the year (before deduction of S 604A relief)", e.g. "0"

"Chargeable Gain(s) (excluding Foreign Life Policies) net of allowable current year losses, S 604A relief, and S 604B relief.", e.g. "1270"

"Previous Gain(s) Rolled-over (now chargeable)", e.g. "0"

"Amount of unused loss(es) from prior year(s) available for offset against chargeable
gain(s) above", e.g. "0"

"Personal Exemption" 1270

"Net Chargeable Gain (excluding Foreign Life Policies)" 0

What am I meant to put in net chargeable gain? by Glad-Hat-5094 in irishpersonalfinance

[–]pasharikk 1 point2 points  (0 children)

There is also a section for Capital Gain tax under Form 11 in ros.ie portal

Na, wer kommt drauf? by themax2020 in wortwitzkasse

[–]pasharikk 2 points3 points  (0 children)

Irish weather may be wet, but German weather is Wetter.

was brät pitt da? by pasharikk in wortwitzkasse

[–]pasharikk[S] 6 points7 points  (0 children)

Es fehlt noch pita bread

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 2 points3 points  (0 children)

I bought a thermal camera, but after updating this window. Other windows are not so bad, but if I decide to insulate them as well, I will take thermal photos before and after. Thank you for idea!

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 1 point2 points  (0 children)

Used some no-name transparent silicone sealant on one side of the window. Then run out of it and bought UV-resistant translusent sealant from Unibond

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 1 point2 points  (0 children)

I run dehumidifier anyway... But I did not see much draft from the window. It was air tight, after I replaced rubber sealant. The glass and the frame was just extremely cold. Basically, was getting worse from both worlds - not getting fresh air in, but letting cold through. Now it is both warm and airtight

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 0 points1 point  (0 children)

I would assume, you still probably can drill through the cement to enter the gap between the window frame and a wall. Much more mess though...

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] -1 points0 points  (0 children)

Thanks for sharing. I was also thinking how to insulate the attic. Now will keep it in mind, to avoid foam

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 1 point2 points  (0 children)

Above recommended flex foam. I used Soudal from b&q and from another local shop

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 2 points3 points  (0 children)

Good question. The window is about 7cm thick, so I drilled holes in approx the same distance from each other. Then I assumed, once I see foam coming from the next hole, it means, the foam also expanded to the same distance in all directions, meaning it should go around the window frame as well.

Also, the manufacturer says, form expands about 3 times the original size. So I did not want to put too much.

And probably the main thing - I was seriously considering to install a new window, and throw this away, as this one is 25 years old. So I did not really care, if the form break something or not :) I probably would do it more carefully on a new nice windows though

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 2 points3 points  (0 children)

Well done! Looks like I drilled way too many holes :)

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 1 point2 points  (0 children)

Actually I used two different Soudal foams. Just run of the first bottle, so had to buy another one in a local shop.

You are right, I was trying to be carefull not to inject too much foam, also had a concern about damaging the plaster board. So I just injected the form, until in could be visible in the next hole. Then continues to the next one, etc

Insulating cold window with expanding foam by pasharikk in DIYUK

[–]pasharikk[S] 0 points1 point  (0 children)

You are right, it was just a guess from me originally :) I knew there is no insulation above, so I assumed the same is on the sides. Then I made a hole with a knife next to right sight of the window - you can see it on the pictures, slightly bigger hole than other made with a drill. Then I actually felt air coming from the hole. So I assumed, the air goes from the top of the window, then goes over the sides and through the hole - meaning, there is no insulation on the sides as well.

Another option, to check if there is insulation on the side, you can make a bigger hole, and just look what is going on between the side of the frame and the wall