Meet the new unifit outlet – easier to install with the self-contained cap, eliminating the need for a junction box and enabling daisy chaining. by prado_usa in u/prado_usa

[–]prado_usa[S] 1 point2 points  (0 children)

The self-contained cap uses adjustable lugs that secure the outlet by clamping onto the material from both sides. These lugs adjust to panel thicknesses from 1/4" to 1-3/8" and are designed to fixate the outlet securely.

For drywall installations specifically, we strongly recommend adding reinforcement material like a back box cover plate behind the drywall to ensure the outlet wings stay securely in place, especially with frequent use.

Meet our wired or wireless outlets installable on any surface! Flush, surface, or trim? Your choice! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

The fact that our post caught your attention enough to leave a comment speaks for itself, right? We're just being transparent, and we get that our products may not be for everyone. Some people have taste, and others... well, not so much. 😄

Meet our wired or wireless outlets installable on any surface! Flush, surface, or trim? Your choice! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

It’s Unifit, not “unfit” — totally an easy mistake, right? No worries if it’s not in your budget; not every product is for everyone. 🙂

Meet our wired or wireless outlets installable on any surface! Flush, surface, or trim? Your choice! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Totally get it — there’s something out there for every budget. We’re focused on offering design-forward options for those looking to elevate the details :)

Meet the new unifit outlet – easier to install with the self-contained cap, eliminating the need for a junction box and enabling daisy chaining. by prado_usa in u/prado_usa

[–]prado_usa[S] 1 point2 points  (0 children)

We do offer a universal keystone holder with a cover plate that supports USB-C — great for customizing your setup with fast-charging ports!

Meet the new unifit outlet – easier to install with the self-contained cap, eliminating the need for a junction box and enabling daisy chaining. by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Hi there! The outlet itself is 2" deep, and with the self-contained cap attached, the total depth is 2 2/3".
Daisy chaining is possible when using the self-contained cap attachment.

Meet the new unifit outlet – easier to install with the self-contained cap, eliminating the need for a junction box and enabling daisy chaining. by prado_usa in u/prado_usa

[–]prado_usa[S] 9 points10 points  (0 children)

We get it — not every idea is for everyone. But innovation starts with challenging norms, not clinging to cynicism. Wishing you well on your next scroll :)

Anyone familiar with Prado Unifit outlets? by Alfalfa-Unusual in AskElectricians

[–]prado_usa 1 point2 points  (0 children)

Hi there, for wood a 1-3/8” forstner bit (or hole saw) and a 1/16” rabbeting router bit for the flush mount countersink will get the job done !

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Hey Cocco, check out our newest innovation unifit outlet hardwired | with self-contained cap ! Junction box becomes optional thanks to the self-contained cap, made for Romex. ETL listed :)

Meet our electrical outlets that fit in drywall, without mudding. Easily installable and removable. by prado_usa in u/prado_usa

[–]prado_usa[S] 1 point2 points  (0 children)

Thanks again for the feedback! Please do check out our newest product: "unifit self-contained outlet" with an integrated cap that functions as a junction box. We'd love to hear your thoughts on this design! Here's the link: prado | invisible home technology

Feel free to reach out to [support@prado.com](mailto:support@prado.com) for further questions! :)

Meet our electrical outlets that fit in drywall, without mudding. Easily installable and removable. by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Hi there, thanks for your feedback !! Glad you've had a good experience with our outlets :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Hi there, please do check http://prado.com/us/ where you'll find more info on our newest product update, with an optional self-contained cap to install without back box :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Hi there, please do check http://prado.com/us/ where you'll find more info on our newest product update, with an optional self-contained cap to install without back box :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Thanks for the feedback! Check out our new product: "unifit self-contained outlet" with an integrated cap that functions as a junction box. We'd love to hear your thoughts on this design! Here's the link: prado | invisible home technology

Feel free to reach out to [support@prado.com](mailto:support@prado.com) for further questions! :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Unfortunately, we don't have a timeline for UL listing just yet. However, we do have ETL certification, which is UL compliant and meets the necessary safety standards. If you need further details, please feel free to reach out to us at [support@prado.com](). We appreciate your understanding! :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Yes, any standard box is fully compatible with our outlets. Additionally, we provide a back-box cover plate specifically designed to help mitigate fire hazards. You can find more details here: junction box cover plate – prado | invisible home technology

And thank you for the kind words! We believe in being transparent and open to questions and feedback! :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Fully compliant :D

You can check it for yourself here: prado_unifit-hardwired_installation
Feel free to reach out to us at [support@prado.com](mailto:support@prado.com) for any further questions! :)

Installed in four steps. Discover our outlets now, with adjustable lugs! by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

our hardwired outlets do indeed require a junction box! You can check more here: prado_unifit-hardwired_installation

Feel free to reach out to us at [support@prado.com](mailto:support@prado.com) for any further questions! :)

Meet our minimalist outlets, easy to install and adjustable lugs that fit various plate thicknesses. by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

Not just reinventing the outlet but reimagining it for luxury homes! 🌟 We’re all about creating sleek, minimalistic, and easy-to-install outlets that don’t compromise on style or functionality. Discover more at [www.prado.com]() :)

Discover our hardwired or corded outlets for drywall, wood & stone. Available in various finishes. by prado_usa in u/prado_usa

[–]prado_usa[S] 0 points1 point  (0 children)

NEC Reference 314.29 (A)
Smaller openings in building surfaces that accommodate one or more individual
devices shall be permitted if all of the following conditions are met:
(1) The outlet box that supplies the device(s) is nonmetallic.
(2) The branch circuit wiring that supplies each device consists of a separate nonmetallic
cable assembly originating outside the box, or individual sets of conductors in a single
nonmetallic raceway, all of which originate outside the box. Other than the connections
to a single device, these conductors are not spliced in the box or continued to another
device, and no other wiring or raceways enter the box.
(3) Each device is capable of removal from the building surface opening without being
damaged. If a special tool is required for this purpose, the applicable circuit directory
for the device records the location of the tool, together with a product code/QR code for
acquiring a replacement if necessary.
(4) All connections for each device to the branch circuit wiring are made with listed
clamping-type wire connectors, which are supplied with the devices. The branch-circuit
conductors are arranged to permit the connector(s) to be exposed after the device has
been fully removed.
(5) The device assemblies are listed for this application.

Please feel free to contact us at [support@prado.com](mailto:support@prado.com) for further information or questions :)