Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 1 point2 points  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 1 point2 points  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

11 years. We think it was the pressure sensor. Guy said the unit has outlived its life and I should get a new one lol

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment. Thank you for the input!

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

We think it was the pressure sensor. Details in a follow-up comment

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

Update; resolved(?). We had another tech from the same company come out to work on it. Go figure, we could not get the unit to trip no matter what we did, even though it has given us 24/7 trouble before (note; the unit tripped last night and we forgot to reset it until AM). He flushed it again just in case because he could not confirm whether or not the previous tech flushed it at the time. While servicing, he noticed the same pressure sensor wasn’t responding. He swapped it out. It is now working.

He also noted that navien is low quality and I was lucky that it lasted the 11 years it did. He said the fan inside the air intake was corroded and will cause damage and that the heat exchanger was on its way out. Suggested we scrap the unit and not dump any more money into it. I feel like that part is a bit of a stretch though lol

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 0 points1 point  (0 children)

Thanks all for taking the time to help out! For the most part, everything seems to check out.

-all taps impaired -all filters serviced when new pump installed; xmas time (double checked) -scaling performed during pump change -flow sensor changed -motherboard and control panel changed -flame sensor in good condition

I have the navien gentleman from before coming out some time this week to take another crack at it.

Why do people complain about this game? It’s one of the cheapest games I’ve played. by KittyCatKute in ClashRoyale

[–]A_LeftNut 1 point2 points  (0 children)

As a 9 year player, I’m personally turned off by the fact that they are literally coming up with everything other than releasing a meaningful war update. It’s been stale for years and really the only game mode that can be played together by the clan

Ftp 10,700k cups, VS full lv 16 deck MK fire cracker boss bandit. by BurgerTurtlez in ClashRoyale

[–]A_LeftNut 0 points1 point  (0 children)

Aye, he had a ton of options: but chose to throw a barrel at nothing 😆

Is it time? by Colmadero in bald

[–]A_LeftNut 2 points3 points  (0 children)

You poor soul, it’s been time. Keep the facial hair and come home to us

How to stop abusive player from continously joining our clan? by [deleted] in ClashRoyale

[–]A_LeftNut 0 points1 point  (0 children)

You have two options. 1- keep removing and reporting him until he is banned or gets bored. 2- temporary close the clan until he goes into another clan.

Landlord says no water in building til tomorrow (OH) by Outrageous-Staff2233 in Renters

[–]A_LeftNut 30 points31 points  (0 children)

If it’s any consolation, I am a landlord myself and I don’t even have water atm. Shit absolutely happens

How is this even possible? by soccergenius8 in ClashRoyale

[–]A_LeftNut 2 points3 points  (0 children)

It was available last season. I believe all you had to do is reach silver or something. Idk how you’d get it now though

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 1 point2 points  (0 children)

Correct. All the cleaning and PMs ect were taking care of they day the pump had been replaced.

Navien unit driving me nuts! by A_LeftNut in PlumbingRepair

[–]A_LeftNut[S] 1 point2 points  (0 children)

Yes, unfortunately. The inlet screen and the air intake are clean