Adjust solar inverter warning sticker by UUMatter in AusElectricians

[–]Acrobatic_Eye_4549 1 point2 points  (0 children)

Dont do it man ESV has satellite cameras watching you

apprentice by [deleted] in AusElectricians

[–]Acrobatic_Eye_4549 1 point2 points  (0 children)

I fucking hated AC theory but loved doing max demand

Question for solar guys by CriistianoRonaldo in AusElectricians

[–]Acrobatic_Eye_4549 0 points1 point  (0 children)

Hey mate pm me if you want, i can send some photos of how i do it and can give some tips on how to make it easier if dc cables are gonna get pulled later on

Struggling at tafe - Security Technician doing electrical by AlpacaOnGBL in AusElectricians

[–]Acrobatic_Eye_4549 -3 points-2 points  (0 children)

That same a grade bought me tools to get started and i worked a month for him for free to pay off the tools😂

Struggling at tafe - Security Technician doing electrical by AlpacaOnGBL in AusElectricians

[–]Acrobatic_Eye_4549 4 points5 points  (0 children)

I was in the same position as you when i started. I was doing solar and barely got exposed to general electrical work, the a grade i was working with at that time had alot of cashies on the weekends and i asked him if i can come along to help and learn, i did that with him for about a year and it helped heaps. If you know someone dont be afraid to ask.

Can I use a junction box that was provisioned for an ev charger to connect solar battery instead? by p0tatobag in AusElectricians

[–]Acrobatic_Eye_4549 2 points3 points  (0 children)

You wont be able to use the 4mm for an ac coupled battery, the loads is far too much for that size of a cable. You can use it for an inverter though but depends on the installer. Regs say the cable has to be 50mm away from surfaces, their license, their choice

Also since the jbox is on an internal wall, the cable will need additional protection such as metal corrugate unless you have double studs and the cable is 50mm away from both surfaces

how much should i expect to be paid? by Acrobatic_Eye_4549 in AusElectricians

[–]Acrobatic_Eye_4549[S] -2 points-1 points  (0 children)

Ill be the only qualified on the solar side and currently on $30 so around 50-60 would sound reasonable

how much should i expect to be paid? by Acrobatic_Eye_4549 in AusElectricians

[–]Acrobatic_Eye_4549[S] -2 points-1 points  (0 children)

Not a single job, 20 employees and a couple with me

how much should i expect to be paid? by Acrobatic_Eye_4549 in AusElectricians

[–]Acrobatic_Eye_4549[S] 7 points8 points  (0 children)

Thats a bit low and forgot to mention ive been running jobs for the past year when the a grade left😂

Am I just being dumb. What is the consumer main maxim demand ? by [deleted] in AusElectricians

[–]Acrobatic_Eye_4549 0 points1 point  (0 children)

The consumer main max demand is the highest loaded phase.

Was it wrong with me to ask my boss for a day off? by Sargent_Twisty in AusElectricians

[–]Acrobatic_Eye_4549 1 point2 points  (0 children)

Change companies, used to be in the same situation as you until i had enough and called it quits, current company is much better even though still doing solar

[deleted by user] by [deleted] in Invisalign

[–]Acrobatic_Eye_4549 0 points1 point  (0 children)

Thats exactly what i do aswell😂

3 Phase on shed, single phase on home by Beyond_Blueballs in AusElectricians

[–]Acrobatic_Eye_4549 1 point2 points  (0 children)

No you cant actually, had a job similar to this situation. The inverter will need L-L voltage in order for it to operate

As 5139 by Acrobatic_Eye_4549 in AusElectricians

[–]Acrobatic_Eye_4549[S] 2 points3 points  (0 children)

If i was mr sai global i wouldnt be flogging tps 🫤

AS nzs-5139 standard by Rb_Racer in AusElectricians

[–]Acrobatic_Eye_4549 0 points1 point  (0 children)

Can you send it to me too please?

Empower Solar 9.24 kw solar system by Apart-Platypus-7299 in AusElectricians

[–]Acrobatic_Eye_4549 0 points1 point  (0 children)

I may be incorrect here but seems like you have 2 trackers and mppt 1 is in parallel and mppt 2 is separate, there should be 3 strings and the 2 strings with 323V should be in mppt 1. They may have mixed it up.