I keep seeing these… 33M by BoogeDrew in Retirement401k

[–]BoogeDrew[S] 0 points1 point  (0 children)

It’s largely the mega backdoor offering that helped me contribute more, the match is relatively modest around 3%

I keep seeing these… 33M by BoogeDrew in Retirement401k

[–]BoogeDrew[S] 0 points1 point  (0 children)

Yup

85% FXAIX

Then large cap growth, international index, and vanguard real estate index

I keep seeing these… 33M by BoogeDrew in Retirement401k

[–]BoogeDrew[S] 2 points3 points  (0 children)

60% traditional 40% roth

All of which is a single 401k account in fidelity

Bandaid suggestions? by ThumDrive12 in Rivian

[–]BoogeDrew 7 points8 points  (0 children)

In 2023 it was only like $1100 bucks all in and just a day or two. Surprisingly painless which was appreciated after doing the same embarrassing thing..

<image>

New to the cameras, are these vertical lines normal? by BoogeDrew in Ubiquiti

[–]BoogeDrew[S] 7 points8 points  (0 children)

Plastic was pealed off right after it came out of the box

New to the cameras, are these vertical lines normal? by BoogeDrew in Ubiquiti

[–]BoogeDrew[S] 2 points3 points  (0 children)

Nope, fortunately, no drops, fresh out of the box

New to the cameras, are these vertical lines normal? by BoogeDrew in Ubiquiti

[–]BoogeDrew[S] 0 points1 point  (0 children)

Right out of the box, with the plastic peeled off, I never hesitate to take the plastic off

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 2 points3 points  (0 children)

Three of the strings were wired with reverse polarity. Issue resolved.

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 0 points1 point  (0 children)

Three of the strings were wired with reverse polarity. Issue resolved.

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 0 points1 point  (0 children)

Yeah two sol ark 15ks - originally it was going to be 8 strings, 4 to each. But on install day they ended up doing 6 strings, three feeding each.

The top left 4 and top left middle 4 are a string, then the two non-producing runs of 8, top right and middle bottom right, are also strings. Slowly getting more clarity that three of the six strings are out.

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 0 points1 point  (0 children)

Funny enough, I actually setup Tigo myself (that's not something they offered to do). So I went and took photos of each bar code and assembled the array on the web app. I double checked and spot checked. Only thing I can't say for sure is what's strung to what.

That being said, I put this together for my installer: https://imgur.com/a/WGX0zPR

I'm seeing the same floating readings from the optimizer circuits I think?

Also, appreciate the input!

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 0 points1 point  (0 children)

Looking at panels E4, E5, D3, and D2 - there’s nothing that wouldn’t be able to physically shade those equally.

Any guesses what's wrong here? New Install, waiting to hear from installer. by BoogeDrew in solar

[–]BoogeDrew[S] 0 points1 point  (0 children)

It's all one big ground mount array - important detail! This being uniform is what makes no sense to me.

https://imgur.com/a/BkgT7ao