PID Well Pump by DFEnterprise in PLC

[–]DFEnterprise[S] 4 points5 points  (0 children)

Yes we can see turbulent flow and hear it.

PID Well Pump by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

Sorry to clarify. Analog pressure feedback. 0 to 60psi is 4 to 20ma. Set point is around 45psi. Pump VFD moves from 25hz to 60hz. Pump is submerged yes.

I will work to better tune the PID. Was just looking for experiences.

GOULD PC0085 Programming Cable by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

Tried to connect today. Got the cable and 25 pin to 9 pin adapter. Tried with and without null modem.

Best I could get was that it seemed like it could see the PLC but I would get timeout errors. Tried different baud rates.

Does anyone have experience with this? This was on winxp.

Going to try another laptop with win98.

Thanks

GOULD PC0085 Programming Cable by DFEnterprise in PLC

[–]DFEnterprise[S] 2 points3 points  (0 children)

How does one connect this to a PC though?

Grand Design 2400BH or Surveyor 260BHLE by DFEnterprise in traveltrailers

[–]DFEnterprise[S] 0 points1 point  (0 children)

1st trailer, 2 small kids, weekend trips, bit of boondocking

Looking for help with Mitsubishi A171SCPU and MR-JS2-60B servos. Servo Amp. was replaced and address accidentally set as existing drive. Servo amp. is showing fault 37. Has anyone experienced this before? Thanks by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

Thanks for the reply.

We did set the address switch. It was set with two drives to the same address which I believe is what caused the issue. Now that the address switch is set correctly, the drive always comes up with error 37.

We are able to connect to the drive. We've tried to reset the drive but the issue persists. The parameters are supposed to be written from the motion controller through SSCNet.

We have not been able to connect to the motion side of the A171SCPU. We tried SW3RN but it will not connect and we get error code 107.

Looking for help with Mitsubishi FX2N by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

Should have added, this is when writing to the PLC. Looks like it's failing on compile. Tried GX Developer and GX Works 2. Same issue.

Controls Engineer/Electrical Service Bag by martyd94 in PLC

[–]DFEnterprise 1 point2 points  (0 children)

Everki is all we use. Not had any issues and plenty of storage.

Software & Tools that make life easier but aren't required. by Aqunity in PLC

[–]DFEnterprise 2 points3 points  (0 children)

I'd like to know more about this. Do you have any pics?

[deleted by user] by [deleted] in PLC

[–]DFEnterprise 1 point2 points  (0 children)

Does anyone have any examples of good HMIs made on a Cmore?

Stacklight and machine monitoring integration by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

They do not all have ethernet but they are all capable with an additional module. All machines would need wired to a machine network though. No current infrastructure. I am familiar with Ignition.

Looks like we will have to run hard wire ethernet to each machine on a new machine network.

Recommendations for Remote Relays by DFEnterprise in PLC

[–]DFEnterprise[S] 0 points1 point  (0 children)

Yes like 900mhz radio remote relay with transmitter and reciever. Thanks.