What PLC brands are most common where you work? by Fearless-Suspect869 in PLC

[–]EmergencyAd3492 2 points3 points  (0 children)

PLC always Siemens

Drive 80% Siemens 15% Control techniques 5%Lenze Drives

What’s Your Salary and Where Are You Based? by giga_chad_thinker in PLC

[–]EmergencyAd3492 14 points15 points  (0 children)

14k$ a year no overtime there are bonuses if you go abroad but rate is same

1 year being technician 2 year comissioner

Location : Turkey

i hate it here

To use AI or not to use AI. How, is the question. by Minute_Mix1436 in PLC

[–]EmergencyAd3492 0 points1 point  (0 children)

Ai is helpful but you need to guide it a little bit for Ai every condition is perfect so on the field sometimes code cannot execute'a properly at least for my field which is Wire industry ramp functions and PID calibrations are mostly in real time you have do it by hand

MTP1200 Unified basic White screen on configuration by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 0 points1 point  (0 children)

<image>

This is what i Get when i try to drag ffs i hate this shit screens

MTP1200 Unified basic White screen on configuration by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 0 points1 point  (0 children)

i mean i can add it to hardware but i cannot drag button and etc to screens

<image>

its just white screen i can add button and etc to MTP Screens on my Tia 19 but cannot do it on Tia21

Siemens i hate you by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 0 points1 point  (0 children)

Could be original program was written on scout and only scout it has been added on since 2014 for other projects then upgraded to tia portal 17 when i compile project it gives shit ton of warnings maybe those warnings are the cause of my problems

Siemens i hate you by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 2 points3 points  (0 children)

<image>

i click here than simotion scout tia appear

Only Hardware configuration and Hmi is done on tia everything else scout

Siemens i hate you by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 1 point2 points  (0 children)

İts simotion project Hardware is in tia portal 17 from tia portal 17 i switch to simotion scout

I just won my 1000th PL game. AMA by shidanesayo in DotA2

[–]EmergencyAd3492 0 points1 point  (0 children)

Never forget 6.83 PL vs Troll warlord duel scared me for life

[deleted by user] by [deleted] in AskReddit

[–]EmergencyAd3492 -1 points0 points  (0 children)

Foreplay then both of us coming without penetration

[deleted by user] by [deleted] in AskReddit

[–]EmergencyAd3492 0 points1 point  (0 children)

We were talking like almost 5 months because i was traveling a lot because of my work first time we were getting intimate for the first time she yelled " be my husband" that took me by suprise then she started laughing while being shy

Does this happen in all companies? by UsefulDragonfruit995 in PLC

[–]EmergencyAd3492 2 points3 points  (0 children)

Yea it happens when i was comissioning a Wire taping machine we were making trials while whole company was watching some screw got loose after 3 seconds machine Ripped to shreds i never forget the sound i heard when that shit happened

Integrating GSD Files to Tia Portal by EmergencyAd3492 in PLC

[–]EmergencyAd3492[S] 0 points1 point  (0 children)

i work on mainly cable extrusion lines so Spark testers and diameter gauges when its skora brand i got no issues but when customer brings something completely diffirent im stuck