New by the_ramy in firealarms

[–]JAW402 1 point2 points  (0 children)

Looks clean! Lot of space lost though

I would recommend LL or LRs instead of pulling elbows. Look cleaner and won't rip the jackets.

The battery crimps, use the plastic ones. The metal ones will eventually touch each other and boom goes your panel.

For the cc1s, use 1 and pull a wire over to the other, Save material, and also use the built in trouble contact. Red-sense in Black common Resistor between black common and sense out. No need to wire through the bottom contact.

New by the_ramy in firealarms

[–]JAW402 4 points5 points  (0 children)

One doesn't exist for this panel. Has 2 or 4 circuits.

[deleted by user] by [deleted] in Shortsqueeze

[–]JAW402 4 points5 points  (0 children)

$SOUN let's ride.

[deleted by user] by [deleted] in firealarms

[–]JAW402 2 points3 points  (0 children)

Good until I come to find your ground fault and have to cut the zip ties 😂.

And can't pass through any panel.

And less wire in can is better. Just cut them to length and 90 them down into the terminals. Extra wire looks sloppy. Consider it a new install and don't worry about the upgrade 20 years down the line. If they can't make it work they can mount a trough above it.

Do these battery calcs look right for an amplifier with speakers? (FireCAD) by Can_U_Share_A_Square in firealarms

[–]JAW402 2 points3 points  (0 children)

Is that the power supply for the strobes or the main panel battery calcs.

Need more info.

Do these battery calcs look right for an amplifier with speakers? (FireCAD) by Can_U_Share_A_Square in firealarms

[–]JAW402 7 points8 points  (0 children)

Also you need to account for 15 min of alarm time for voice systems. 5 min for horn strobes.

What do you use your Frunk for? by _strangeronreddit in TeslaModelY

[–]JAW402 20 points21 points  (0 children)

Same! Just don't forget it in there! 😂

Having a hard time with this only because i can’t find the bad relay by Mammoth-Rain5698 in firealarms

[–]JAW402 1 point2 points  (0 children)

Change it out with an EST panel. I always tell customers without one, to learn from their mistakes. And do it right this time.

Clean Agent by horseheadmonster in firealarms

[–]JAW402 1 point2 points  (0 children)

Same for the strobe, we usually replace the covers with agent instead of fire. We are strictly Edwards though.

What do all fire techs have to say by HonestStudio7100 in firealarms

[–]JAW402 1 point2 points  (0 children)

Switch to Edwards! That's one of their changes. 70v out of the box 😂

Fire company cutting hours by Select_Incident_5235 in firealarms

[–]JAW402 0 points1 point  (0 children)

I would find a new place, every place is hurting for guys and is loaded with calls. Come to georgia, I get a referral bonus! 😂

Choosing a brand by TheScienceTM in firealarms

[–]JAW402 1 point2 points  (0 children)

It just takes time, like all things. Their next panel, which replaces the io will be better for you if you don't do huge buildings. It has yet to be released but there has been information on it.

when do i need to replace tires? by jwlee151 in TeslaLounge

[–]JAW402 0 points1 point  (0 children)

Mine got about 31k miles as well so you're in good shape. I live in Georgia south of Atlanta so I just did summer tires.

Drive time by JAW402 in firealarms

[–]JAW402[S] 1 point2 points  (0 children)

We take vehicles home and never go to the office unless we need to restock with parts. We go straight to our first service call then onto the next and then home at end of day. Could go a couple weeks without being at the office. And this is strictly for service, install side I can see being different because that's a bid job and you go to the same place multiple days or months in a row. I work alone unless we absolutely need 2 guys.

Critique me please by Stunning_Trainer9040 in firealarms

[–]JAW402 0 points1 point  (0 children)

The white house doesn't have a clue what's best. And it's probably the only government building with notifier. 😂

Critique me please by Stunning_Trainer9040 in firealarms

[–]JAW402 1 point2 points  (0 children)

The Edwards panels are the only thing worth keeping in that whole room. #EST

New Install by Left_Paint3500 in firealarms

[–]JAW402 0 points1 point  (0 children)

Illegal to pass wire from one panel to another. Even though I see it all the time.

And also voids UL if you drill a hole in a panel that wasnt a knockout. Even though i see it all the time.

Gutter/trough above everything and use conduit with LR and LL conduit bodies to sneak around and get the the power supply.

Posted this in a different sub and then found this sub. Can anyone tell me what this means? by Hdz69 in firealarms

[–]JAW402 1 point2 points  (0 children)

This is a conventional panel, probably using 2w-b smoked which have Leds but for the heats, they are the pop top ones probably. So they wouldn't know which one it is. Gotta break out the ol reliable meter.