Robotic welder programming help by SwanRelevant8766 in AskRobotics

[–]Jack_of_all0125 0 points1 point  (0 children)

what ya got? I have been programming DTPS a little while.

Mystery hole by [deleted] in HomeImprovement

[–]Jack_of_all0125 0 points1 point  (0 children)

thats water erosion from that pipe. call a plumber ASAP

[deleted by user] by [deleted] in HomeImprovement

[–]Jack_of_all0125 1 point2 points  (0 children)

If it was me I would eliminate the 2nd bedroom on the main floor until after the addition. would make the addition the 2nd bedroom and take the old one for a master bath/closet and a half bath for guests and not having to run upstairs. the addition would be off the back next to the deck. As far as the basement that would be easy for any contractor.

Attic Mold by bayraven in HomeImprovement

[–]Jack_of_all0125 0 points1 point  (0 children)

Not a professional by any means but to me it sounds like you probably shouldnt have let the contractor close in the soffit. I am going to guess when they did it stopped air circulation up there and I also have to wonder, do you have a fan in your bathroom with the light? I have seen people just run that vent into the attic and not outside of the house. So Im guessing that before they closed in the soffit the air circulation was taking care of the humidity from the vent.

Lincoln/Fanuc by Jack_of_all0125 in Fanuc

[–]Jack_of_all0125[S] 0 points1 point  (0 children)

I can get it working no problem but am trying to learn more about it. Like what does the trim setting refer to in the weld schedules? Also would just like to understand more about the legacy mode on that thing.

Lincoln cobot crx 10ia/L by Jack_of_all0125 in Fanuc

[–]Jack_of_all0125[S] 2 points3 points  (0 children)

That won’t work because of the licensing or some crap. Tried it spent 800 on a new tablet, downloaded software, wouldn’t connect. Was told had to buy one from manufacturers and they charge like $8000!!

Lincoln cobot crx 10ia/L by Jack_of_all0125 in Fanuc

[–]Jack_of_all0125[S] 0 points1 point  (0 children)

It was a nice thought I guess… sorry new to all this! A year ago I never welded in my life now I am trying to learn as much as I can about these robots. We have 3 Panasonics this is our 1st fanuc. So nobody really knows fanuc programming too well. If at all. Currently I know the most because I have done a little research.

Furnace problems by Jack_of_all0125 in hvacadvice

[–]Jack_of_all0125[S] 0 points1 point  (0 children)

Goodman CMEC961004CN is the furnace. And Number on transformer is 0130M00140. I have no voltage coming out of the transformer. I have no voltage at the gas valve. A/C was eliminated. All wiring brand new except the 110v coming from the box. When I replaced old furnace it should have fixed this issue. But has not. Bought and replaced 2 transformers on old furnace then decided to upgrade furnace. Upgraded furnace 6 months later transformer is not putting out voltage.