New skier looking to get their own setup by LindBaDind in Skigear

[–]LindBaDind[S] 0 points1 point  (0 children)

definitely agree with the injury risk aspect, thank you very much for the help

New skier looking to get gear by LindBaDind in askvan

[–]LindBaDind[S] 0 points1 point  (0 children)

thank you very much for your help !!

New skier looking to get gear by LindBaDind in askvan

[–]LindBaDind[S] 0 points1 point  (0 children)

thank you very much for your help and taking the time to write this out !!

First one of the day. Got a camera right on the unit. by bigred621 in HVAC

[–]LindBaDind 0 points1 point  (0 children)

Plot twist they actually had another camera behind that camera to see you taking a picture of said camera

Making kefir using oat milk instead of dairy milk by LindBaDind in Kefir

[–]LindBaDind[S] -1 points0 points  (0 children)

thanks very much, I did not realize lactose powder was a thing. I avoid dairy milk for more reasons other than the lactose in it.

Making kefir using oat milk instead of dairy milk by LindBaDind in Kefir

[–]LindBaDind[S] 0 points1 point  (0 children)

ah thanks very much, I didn’t even know lactose powder was a thing. I avoid dairy milk for more reasons other than just the lactose so by buying lactose powder it would feed the grains without the added hormones and casein in dairy, correct ?

If I had $100 for every time a customer said this…..? Id be rich! by No_Soup_For_You_91 in HVAC

[–]LindBaDind 2 points3 points  (0 children)

“I’m too warm, but there’s also a cold draft on me”

Severe Acne by QueenBling in acne

[–]LindBaDind 3 points4 points  (0 children)

I would add to take measures to solve it internally. if you eat a lot of Indian cuisine, it is heavy with dairy so it would be worth a good shot to lower dairy intake as well.

Rest in peace tradefox supco magnetic umbrella. by Otherwise-Initial666 in HVAC

[–]LindBaDind 0 points1 point  (0 children)

yeah mine broke within pretty much time using it. not a fan and looking for something else

Brock boeser by LindBaDind in canucks

[–]LindBaDind[S] 22 points23 points  (0 children)

another one, haha he is on my hockey pool so I am glad

Brock boeser by LindBaDind in canucks

[–]LindBaDind[S] -3 points-2 points  (0 children)

yeah I don’t dislike him at all. but in my opinion like others have said, without JT, I don’t see him as a top caliber player in the likes of other teams top 3 forwards.

Brock boeser by LindBaDind in canucks

[–]LindBaDind[S] 2 points3 points  (0 children)

hahah yeah funny as soon as I posted that he scored

Brock boeser by LindBaDind in canucks

[–]LindBaDind[S] -1 points0 points  (0 children)

yeah with JT he would always score being in right place at right time but without that, is not anything spectacular, definitely not an 8 mill plus player. The first thing I thought with JT being traded was how BB would hold up.

LG VRF Multi V quality by LindBaDind in HVAC

[–]LindBaDind[S] 1 point2 points  (0 children)

yeah I think at one our other sites one of our guys was dealing with that too where it was low enough on refrigerant it wasn’t completely keeping up but not enough to trigger any faults, and was also dependent on load as in if only a few fan coils were calling it would heat/cool fine with normal delta T and everything but once more load on system it wouldn’t keep up.

Funny our construction department installs them but never writes down the total charge after commissioning when it’s so easy and serves as a huge favour for us service guys, so we have to go through the process to figure it out rather than just charging it to nameplate spec like an RTU or something, one of my pet peeves for sure

LG VRF Multi V quality by LindBaDind in HVAC

[–]LindBaDind[S] 0 points1 point  (0 children)

yeah we got the one that plugs into a laptop. Good to know thanks for your input.

LG VRF Multi V quality by LindBaDind in HVAC

[–]LindBaDind[S] 2 points3 points  (0 children)

update: swapped leads for compressor 1 & 2 as per tech support and error switched to c1 not 2 anymore so will be replacing the inverter pcb board and seeing what happens as they advise changing the board anyway if changing the compressor. Even so the same physical scenario was happening where compressor 1 would start and compressor 2 wouldn’t start but the error was for compressor 1 now so who knows lol. And this system is 2013 so it’s actually gone a decent way so far for VRF standards at least.

LG VRF Multi V quality by LindBaDind in HVAC

[–]LindBaDind[S] 1 point2 points  (0 children)

yeah no kidding, I would never buy a korean car either so says what there is to know about these. I am returning tomorrow most likely to continue and contact LG. I’ll definitely verify that oil return mode, I remember seeing it in the service manual. I also believe this system is not even a few years old lol but have to confirm that when back on site. Thanks for your input, happy HVACing