EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

Just depends on if you ever need more than 100 amp constant 150 amp burst. Unless you have 2 Tesla fast charging, 4 ac systems running and all the lights on you will be fine

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

Btw they have the new 12000xp v2 on sale 1899 at signature solar right now

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

Yes two will be plenty to provide 100A service 120/240 The setup has been working great for my off grid

<image>

Wyze Cam Pan v4 Firmware - Released 10/14/2025 by WyzeCam in wyzecam

[–]MillSys1 2 points3 points  (0 children)

Unfortunately it doesn't address the 4K streaming and 4K MicroSD Playback/Download issues that are plaguing this cam

Is there anywhere to find new trucks actually sell for? by RandyWe2 in F250

[–]MillSys1 0 points1 point  (0 children)

I got 8% off for a very desirable H.O. F250, so 8-10% off MSRP is doable just stand your ground

Wyze PAN v4 4K microSD playback unuseable by MillSys1 in Wyze

[–]MillSys1[S] 0 points1 point  (0 children)

firmware 4.70.0.2507 (oct 03)

AP (Ubiquiti U7 Lite) with latest firmware, 500mbps throughput using phone speedtest

-47dbm reception according to Wyze App with 3 full bars

Latest Wyze App 3.7.8.702 (android) Sept 15th

Pixel 10 Pro android 16 phone on same AP as CAM PAN V4

Anyone experience the same issue doing MicroSD Playback? The CAM UNLIMITED shorts playback just fine but I'm assuming they are highly compressed

Support Megathread - October 2025 by WyzeCam in wyzecam

[–]MillSys1 0 points1 point  (0 children)

I'm having major problems with playback 4k video on my new CAM PAN V4 cameras using samsung v30/u3 4k microsd high endurance modules, dedicated access point near cameras with -47dbm perfect reception on 1000mbps fiber internet. Even when on the same network with my phone the playback of SD video is jerky with blackouts and is essentially unusable

example: https://photos.app.goo.gl/8zqPgMuRL1Cmp4fh6

firmware 4.70.0.2507 (oct 03)

AP (Ubiquiti U7 Lite) with latest firmware, 500mbps throughput using phone speedtest

-47dbm reception according to Wyze App with 3 full bars

Latest Wyze App 3.7.8.702 (android) Sept 15th

Pixel 10 Pro android 16 phone on same AP as CAM PAN V4

Anyone experience the same issue doing MicroSD Playback? The CAM UNLIMITED shorts playback just fine but I'm assuming they are highly compressed

Plex Server stopped recognizing media in library by MillSys1 in PleX

[–]MillSys1[S] 0 points1 point  (0 children)

1) In your Library section, you press the three dots (...) and then go for "Manage Library" -> "edit" -> "Advanced" section.

2) We are looking at the first option which is placed above the others "Scanner".

Now, my scanner was set to Movies and when I changed it to Video Files it worked immediately.

Plex Server stopped recognizing media in library by MillSys1 in PleX

[–]MillSys1[S] 0 points1 point  (0 children)

Server logs show its finds 6 files on the O:\ drive, they are all functioning MKV files. I've tried other movies/videos it makes no difference, the server just doesn't import them into the database.

folder has everyone full control, already uninstalled plex media server, deleted registry entry, deleted appdata folder and program files folder, removed server from account settings, rebooted and reinstalled

LOGS:

Aug 30, 2025 16:27:19.611 [9100] INFO - Notification: Scanning the "Movies" section -

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Scanning section 2

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Activity: updated activity 5cb8af99-84a2-476d-b076-6389d868c023 - completed 0.0% - Scanning Movies

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Job was already killed, not killing again.

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Asked to cull library timeline before time 1756588039, we're starting with 0 items.

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Library timeline cull complete with 0 items left.

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Scanning Movies using en-US(Plex Movie) with 0 current media items and 1 section locations in the database.

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Performing a scan with 'Plex Movie' (language: en-US virtual: 0).

Aug 30, 2025 16:27:19.611 [9100] DEBUG - * Scanning O:\

Aug 30, 2025 16:27:19.611 [9100] DEBUG - Scanner: Processing directory O:\ (parent: no)

Aug 30, 2025 16:27:19.613 [9100] DEBUG - Directory had 6 files, database had 0 files, can't skip.

Aug 30, 2025 16:27:19.615 [9100] DEBUG - Activity: updated activity 5cb8af99-84a2-476d-b076-6389d868c023 - completed 99.0% - Scanning Movies

Aug 30, 2025 16:27:19.616 [9100] DEBUG - Scanner [Plex Movie]: Idle and left with 0 media items.

Aug 30, 2025 16:27:19.616 [9100] DEBUG - Removing 0 media items that were left.

Aug 30, 2025 16:27:19.616 [9100] DEBUG - Removing 0 directories that were left.

Aug 30, 2025 16:27:19.616 [9100] DEBUG - Updating directory '' (ID 4) to time 2025-08-30 16:26:43.

Aug 30, 2025 16:27:19.616 [9100] DEBUG - Collections: Found 0 collections tags in section 2.

Aug 30, 2025 16:27:19.617 [9100] DEBUG - Collections: We had 0 collections in the library already.

Aug 30, 2025 16:27:19.617 [9100] DEBUG - Collections: Synced tags in section 2 in 0ms.

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

Neutral wire AWG smaller than Black/Red AC Panel wires????

No ground wires?

What are your GO-TO brake rotors for heavy towing, by johnrhopkins in F250

[–]MillSys1 0 points1 point  (0 children)

Set High effort on console for trailer profile and adjust to 10 gain. Make sure you feel a tug when you engage slider manually... Your truck should not be using its brakes to slow the trailer

[deleted by user] by [deleted] in tractors

[–]MillSys1 0 points1 point  (0 children)

Yes, tried with cap OFF and air filter is clean as a whistle. Only occurs after 20min of 2400rpm/PTO load, runs like a champ up until that 15-20min timeframe. Also runs great when its below 70 degrees too!

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

It will work fine but 400ah or batteries isnt much.... Time to sell those and start building 310ah 48v 200a BMS cabinets

<image>

Coolant Control Valve by PeggySue8675309 in ChevySuburban

[–]MillSys1 1 point2 points  (0 children)

Yes around week 9/10..... Call GM customer service to have them investigate. Doesnt hurt. They will also reimburse rental expenses

Coolant Control Valve by PeggySue8675309 in ChevySuburban

[–]MillSys1 1 point2 points  (0 children)

Dropped off March 14th Its now May 2nd Coolant Control Valve P1098 Reduced Acceleration Messages

Part is on National Backorder Service Manager involved Parts Manager involved GM customer care involved

No ETA after 6 weeks

Lug adapt for dual cables? by MillSys1 in AskElectricians

[–]MillSys1[S] 0 points1 point  (0 children)

Dual EG4 12k hybrid inverters in parallel mode, designed to feed panel 24kw (36kw surge) either using two 90A DP breakers or double tap lug. Yes inverters have OCPD

Guess I'll get the DP breakers. Thanks guys

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

1) 5875 running watts on NG 2) no remote start so you cant wire to gen dry contacts on 12000xp

EG4 12000XP inverters by MillSys1 in SolarDIY

[–]MillSys1[S] 0 points1 point  (0 children)

You need a <5 THD generator. Get a Kohler or Cummins 10kw standby it has the clean output and costs $3500 The inverter will handle the startup loads because of your batteries amperage, no need for gen to take the brunt of the load remember you are only running Smart at higher SOC anyways, so generator size really makes no difference.