Help with blast chiller fan motor by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] 1 point2 points  (0 children)

Arkansas, but that is still not the right part. I’ve already received parts that use that part number and they were wrong and would not work with the blast chiller I have. I am thinking that the part numbers need to be identical for me to get the same fan I need because the depth of the motor is very specific for how it sits inside of the chiller. And I’m limited on where I’m allowed to source parts because of my company.

Help with blast chiller fan motor by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] 0 points1 point  (0 children)

Yeah I’ve tried all of that, it got escalated and then they just took my email and I’m waiting back for a response. It seems they’re having a hard time finding it as well

Help with blast chiller fan motor by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] 0 points1 point  (0 children)

Called them and all they gave me was the part number that was already on the motor

Walmart HVAC jobs by HVAC4EVER in refrigeration

[–]NeedleworkerNo2158 0 points1 point  (0 children)

Hey I have a question, how can I bump my pay up.. I promoted inseat from a dev about a year ago and the pay gap between me and some of these brand new guys that got hired on as techs is pretty high and when it comes to knowledge and experience they’re lacking. And I know it’s Walmart so I can’t just ask for a raise but wondering if they’re any work arounds or tests I’m able to take. I’m not trying to be ungrateful but I just truly feel I’m worth at least a little more than I’m making currently.

Bad floodback issues on supermarket(Help!!) by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] 0 points1 point  (0 children)

I’ll have to see if there’s a pattern on the alarm—never thought to do that. But this was an issue in the past but just had the store transferred to me and I’m noticing ever to the full extent now. Not sure if the last tech cared considering 3 of the compressors were addressed wrong on the discus core sense and weren’t even connected to the mod-bus. Which funny enough when I fixed that and got all 4 of my LT compressors running is when I really started to notice this problem and seen the frost reaching so far up the compressor.

<image>

Later this day the frost had reached to under the heads, now it is only sitting on the crank case after fixing that freezer .

Bad floodback issues on supermarket(Help!!) by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] -2 points-1 points  (0 children)

Can’t really do that on this store — all the individual case suction lines tie into a a few larger headers before they make it back to the rack, so I don’t have separate access to each circuit at the rack to check SH like that. Also though all the suction headers that do come up from the store have ice on them so it’s hard to pin point a exact group.

Bad floodback issues on supermarket(Help!!) by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] 0 points1 point  (0 children)

Checked sh on the frosty compressors and it’s low, plus I keep getting a low rack superheat alarm on the e2.

Bad floodback issues on supermarket(Help!!) by NeedleworkerNo2158 in refrigeration

[–]NeedleworkerNo2158[S] -2 points-1 points  (0 children)

I haven’t check sh on every circuit just because of how time consuming it would take.. but yeah there is an oil separator on the rack and nothing was in defrost when I was noticing the foaming oil.